Search PubMedSearch

PubMed · 8551265

Serum anti-p24 antibody concentration has a predictive value on the decrease of CD4 lymphocyte count higher than acid-dissociated p24 antigen.

Abstract

We studied the prognostic value on the decrease of CD4 lymphocyte count of anti-p24 antibody (ab) titer and compared this value with that of polyclonal and monoclonal p24 (ag) titer before and after immune complex dissociation (ICD); 53 human immunodeficiency virus (HIV)-infected patients having CD4+ counts above 400/mm3 when first examined were followed up over a 3-year period including at least four visits; HIV disease progressors (n = 18) were defined as having CD4+ counts below 200/mm3 and non-progressors (n = 35) as having CD4+ counts still above 400/mm3 at the end of follow-up. Sera were collected at each visit and assayed for p24 ag with and without ICD and for anti-p24 ab titer. The mean anti-p24 ab titer of progressors and of non-progressors at entry was significantly different. A threshold of anti-p24 ab titer indicating a HIV progression was determined at 1/300. The proportion of individuals with an anti-p24 ab titer lower than 1/300 at least once during the study period was 34% in non-progressors and 94% in progressors. The difference between progressors and non-progressors at entry was significant with monoclonal p24 ag without ICD and more significant with monoclonal p24 ag after ICD. The marker having the highest predictive value was the anti-p24 ab titer, then monoclonal p24 ag with ICD, then polyclonal p24 ag with ICD. Anti-p24 ab is an earlier and stronger marker of the decrease of CD4 lymphocyte count than p24 ag even after ICD.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Morand-Joubert, H Bludau, J Lerable, J C Petit, J J Lefrère. 1995. Serum anti-p24 antibody concentration has a predictive value on the decrease of CD4 lymphocyte count higher than acid-dissociated p24 antigen.. https://doi.org/10.1002/jmv.1890470116

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reversed-phase high-performance liquid chromatography of ionogenic compounds: comparison of retention models.

Two kinds of retention models describing a behaviour of ionogenic substances in reversed-phase chromatographic systems were compared. Model A utilises a concept of limiting retention factors and is especially suitable for the prediction of retention of compounds co-existing in several forms in mobile phase. An effect of the concentration of organic modifier (e.g., methanol) on the magnitudes of the limiting retention factors and equilibrium constants (dissociation constants of the separated substances) can be expressed with the aid of various, more or less sophisticated, relationships. A stoichiometric displacement model (model B) in its original form simply relates the analyte retention to the content of organic modifier in the mobile phase. In this work, it was modified to also express an effect of the mobile phase pH introducing side equilibria (acid-base) into the model. Both models predict a sigmoidal dependence of the analyte retention factor on the mobile phase pH in accordance with experimental data, and allow, among others, to estimate dissociation constants from those data. Experimental dependencies between the analyte retention and the concentration of methanol in the mobile phase comply well with model A, whereas the stoichiometric displacement model could be used only in a limited range of the methanol concentrations.

Acids

Quinine versus carbamoylated quinine-based chiral anion exchangers. A comparison regarding enantioselectivity for N-protected amino acids and other chiral acids.

First, a chiral stationary phase was prepared by immobilization of the naturally occurring alkaloid quinine onto a 3-mercaptopropyl-modified silica gel via a radical addition reaction and it was evaluated for direct HPLC enantioseparation of acidic chiral compounds under buffered hydro-organic mobile phase conditions. Second, its enantioselectivity and retention characteristics for a representative set of N-derivatized alpha-amino acids and other chiral acids were compared with those of a similar weak chiral anion exchanger based on tert.-butyl carbamoylated quinine derivative as chiral selector. The results clearly indicate that the introduction of the carbamoyl functionality at the secondary hydroxyl group at C9 of quinine provides new and additional sites for intermolecular interactions with chiral analytes and this can profoundly change and improve chiral recognition ability, especially for amide, carbamate and sulfonamide derivatives of amino acids including DNB, Bz, Ac, For, Z, Fmoc, Boc and DNS-protected amino acids. The impact of this new and rigid hydrogen donor-acceptor group--directing stereoselective selector-selectand complexation by intermolecular hydrogen bonding--in comparison to the plain quinine selector is further evaluated by alkylation of the nitrogen atom of either the selector carbamate and/or of the amino function of leucine (N-methyl leucine) derivatized either by DNB or DNP groups.

Acids

Does bottle type and acid-washing influence trace element analyses by ICP-MS on water samples? A test covering 62 elements and four bottle types: high density polyethene (HDPE), polypropene (PP), fluorinated ethene propene copolymer (FEP) and perfluoroalkoxy polymer (PFA).

Groundwater samples from 15 boreholes in crystalline bedrock aquifers in South Norway (Oslo area) have been collected in parallel in five different clear plastic bottle types (high density polyethene [HDPE], polypropene [PP, two manufacturers], fluorinated ethene propene copolymer [FEP] and perfluoroalkoxy polymer [PFA]. In the cases of polyethene and polypropene, parallel samples have been collected in factory-new (unwashed) bottles and acid-washed factory-new bottles. Samples have been analysed by ICP-MS techniques for a wide range of inorganic elements down to the ppt (ng/l) range. It was found that acid-washing of factory-new flasks had no clear systematic beneficial effect on analytical result. On the contrary, for the PP-bottles concentrations of Pb and Sn were clearly elevated in the acid-washed bottles. Likewise, for the vast majority of elements, bottle type was of no importance for analytical result. For six elements (Al, Cr, Hf, Hg, Pb and Sn) some systematic differences for one or more bottle types could be tentatively discerned, but in no case was the discrepancy of major cause for concern. The most pronounced effect was for Cr, with clearly elevated concentrations returned from the samples collected in HDPE bottles, regardless of acid-washing or not. For the above six elements, FEP or PFA bottles seemed to be marginally preferable to PP and HDPE. In general, cheap HDPE, factory new, unwashed flasks are suitable for sampling waters for ICP-MS ultra-trace analysis of the elements tested.

Acids