Continuous radial data acquisition for dynamic MRI.

Abstract

Since image acquisition times in MRI have been reduced considerably over recent years, several new important application areas of MRI have appeared. In addition to pure static anatomic information, the evolution of a dynamic process may be visualized by a sequence of temporal snapshots of the process acquired within a short time period. This makes applications like interactive or interventional MRI as well as the acquisition of additional functional information feasible. For high temporal resolution, all these applications require a quasi real-time image acquisition during the time the interaction or dynamic process evolves. We present an approach to real-time imaging using a continuous radial acquisition scheme. The intrinsic advantages of radial or projection reconstruction (PR) techniques are used to minimize motion-related image distortions. Modifications of the acquisition scheme as well as dedicated reconstruction techniques are used to further reduce the temporal blurring due to the finite acquisition time of one entire data set in our approach. So far we have used this technique for the visualization of active joint motion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Rasche, R W de Boer, D Holz, R Proksa. 1995. Continuous radial data acquisition for dynamic MRI.. https://doi.org/10.1002/mrm.1910340515

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗