The rectal electric activity or electrorectography was recorded transcutaneously in 24 healthy volunteers (mean age 39.6 years). A silver-silver chloride electrode was applied lateral to each of the two sacroiliac joints, and a third one was placed midway between the left greater trochanter and the ischial tuberosity. The reference electrode was applied to the right lower limb. At least two 20-min recording sessions were performed for each of the 24 subjects. In addition, an intrarectal electrorectographic recording was done in 10 of the 24 subjects using silver-silver chloride electrodes attached to the rectal mucosa by suction. Pacesetter potentials (PPs) were recorded transcutaneously. The wave was triphasic with a small positive, a large negative and another small positive deflection. PPs had a regular rhythm and were reproducible. The mean frequency was 3.1 cycles/min. The transcutaneously recorded PPs could be confirmed by the intrarectal route. Both routes had similar electrorectographic recordings, except for the action potentials (APs) which did not show in the transcutaneous electrorectogram. In conclusion, the study demonstrates that PPs could be recorded transcutaneously. Transcutaneous electrorectography is simple, easy, reproducible and cost-effective, and may prove to be a useful investigative tool in the diagnosis of anorectal disorders.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Shafik, A Nour, A Abdel Fattah. 1995. Transcutaneous electrorectography: human electrorectogram from surface electrodes.. https://doi.org/10.1159/000201279

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrocholedochogram: a study of the electromechanical activity of the common bile duct in the dog.

The electromechanical activity of the common bile duct (CBD) was studied in 11 dogs aiming at elucidating the mechanism of bile transport through the CBD as well as at characterizing a normal electrocholedochogram that could act as a standard for the pathologic conditions. After opening the abdomen under anesthesia and exposing the CBD, the electric activity of the CBD was recorded by 2 electrodes sutured to its serosa and the pressure registered by a perfused catheter introduced into the CBD. The effect of CBD distention and myotomy on its EMG activity was tested. Slow waves or pacesetter potentials (PPs) were recorded exhibiting the same frequency, amplitude, and velocity of conduction from the 2 electrodes of each dog on all test days. They were followed by action potentials (APs) which were inconsistent and associated with a rise in the CBD pressure. These variables were higher postcibally than in the fasting state (p < 0.05). They increased on balloon-produced distention of the CBD. The caudad direction of PPs and APs was evident when, following the CBD myotomies, the signals appeared from the segment proximal but not distal to the cut. The study demonstrated that the CBD possesses an electric activity which seems to be responsible for the motile activity of the duct. Furthermore a normal "electrocholedochogram" was characterized which is expected to exhibit changes in pathologic conditions of the CBD. It is proposed that the electrocholedochogram could act as an investigative tool in the diagnosis of CBD disorders, provided it could be performed transcutaneously.

Action Potentials