Search PubMedSearch

PubMed · 8531252

Root coverage techniques: a review.

Abstract

Gingival recession with the exposure of root surfaces is a significant treatment problem facing the clinician. Controversy relative to treatment continues and centers primarily around the need for gingival width augmentation. In 1972, Lang and Löe advanced the concept that a true minimal width of keratinized gingival tissue was necessary for health. They showed that all surfaces with less than 2 mm of keratinized gingiva exhibited clinical inflammation and varying amounts of gingival exudate. In contrast, 80% of the surfaces with more than 2 mm of keratinized gingiva were clinically healthy, and 76% of these same surfaces failed to show gingival exudate. Since 1972, the majority of studies have found that minimizing inflammation is sufficient to maintain attachment levels, even in the absence of "adequate" widths of keratinized and attached gingiva. Certain situations may enhance recession, such as subgingival restorations and toothbrushing trauma, but if inflammation is controlled and the etiology eliminated, minimal amounts of keratinized gingiva can be maintained in a state of health without further recession. Such findings have led to the current concept that deemphasizes a need for gingival augmentation surgery when there is no accompanying need for root coverage. A requirement for root surface coverage arises when gingival recession has esthetic implications, where exposure has resulted in root sensitivity, or where recession complicates routine home care procedures. While agreement exists relative to the indications for root coverage, there are a variety of surgical techniques that can accomplish this end. The purpose of this paper is to review these techniques and to examine the indications for choosing one procedure over another.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V J Tackas. 1995. Root coverage techniques: a review.. https://pubmed.ncbi.nlm.nih.gov/8531252/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The relative amount of epithelium, muscle, connective tissue and lumen in prostatic hyperplasia as a function of the mass of tissue resected.

PURPOSE: The relative amounts of epithelium, connective tissue, muscle and gland lumen in benign prostatic hyperplasia have been reported but they have not been correlated with prostate size. We determine if the relative amount of prostatic tissue varies with prostate size. MATERIALS AND METHODS: Paraffin blocks of transurethrally resected prostate tissue were randomly chosen from the archives of 58 patients with benign prostatic hyperplasia. Two new slides per patient were made and stained with prostate specific antigen or Masson trichrome, respectively. A total of 20 images from each slide were captured using a high resolution camera, digitized and analyzed with computer software for the relative percentage of the various tissue components. RESULTS: As the amount of prostate tissue resected increased from less than 10 to greater than 70 gm. the epithelium had a 4-fold increase from 5.37 to 21.92%, the muscle component had a 42% decrease from 28.46 to 16.62%, the lumen doubled from 7.05 to 14.01% and the connective tissue remained relatively unchanged from 35.58 to 31.53%. There was a statistically significant difference in all components of prostatic tissue except for connective tissue when comparing prostates less than 30 versus greater than 30 gm., including epithelium 6.52 versus 16.10% (p <0.01), muscle 28.45 versus 20.78% (p <0.01), lumen 7.42 versus 14.58% (p <0.01) and connective tissue 35.74 versus 32.45% (p <0.06). The stroma-to-epithelium and muscle-to-epithelium ratios each had a 9-fold decline (p = 0.01). CONCLUSIONS: As the prostate increases in size, there is statistically significant more epithelium and lumen, and less muscle tissue.

Connective Tissue

Thrombin stimulates fibroblast procollagen production via proteolytic activation of protease-activated receptor 1.

Thrombin is a multifunctional serine protease that has a crucial role in blood coagulation. It is also a potent mesenchymal cell mitogen and chemoattractant and might therefore have an important role in the recruitment and local proliferation of mesenchymal cells at sites of tissue injury. We hypothesized that thrombin might also affect the deposition of connective tissue proteins at these sites by directly stimulating fibroblast procollagen production. To address this hypothesis, the effect of thrombin on procollagen production and gene expression by human foetal lung fibroblasts was assessed over 48 h. Thrombin stimulated procollagen production at concentrations of 1 nM and above, with maximal increases of between 60% and 117% at 10 nM thrombin. These effects of thrombin were, at least in part, due to increased steady-state levels of alpha1(I) procollagen mRNA. They could furthermore be reproduced with thrombin receptor-activating peptides for the protease-activated receptor 1 (PAR-1) and were completely abolished when thrombin was rendered proteolytically inactive with the specific inhibitors d-Phe-Pro-ArgCH2Cl and hirudin, indicating that thrombin is mediating these effects via the proteolytic activation of PAR-1. These results suggest that thrombin might influence the deposition of connective tissue proteins during normal wound healing and the development of tissue fibrosis by stimulating fibroblast procollagen production.

Connective Tissue

Analysis of titanium dental implants after failure of osseointegration: combined histological, electron microscopy, and X-ray photoelectron spectroscopy approach.

A multitechnique approach has been used to characterize the surface of nonosseointegrated titanium implants and the surrounding biological tissues. Five pure titanium dental implants were used as reference, and 25 removed implants were studied. Surface and in-depth chemical compositions of the implants (from a total of 16 patients) were investigated by X-ray photoelectron spectroscopy (XPS). Histological slides of the surrounding tissues were examined by light microscopy, XPS, and electron microprobe analysis. None of the failed implants presented the regular surface composition and depth profile of the TiO2 overlayer; foreign elements (Ca, Na, P, Si, Cl, Zn, Pb, and Al) were observed on some implants. Fibrosis, lymphocytic and plasmocytic infiltrates, and granulomatous lesions were detected in the surrounding tissues. XPS and electron microprobe analysis indicated the presence of Zn, Fe, Sn, and Ti in the tissues. As a possible scenario for implant failure, we propose and discuss a oxidoreduction mechanism, leading to a partial dissolution or the complete dissociation of the protective titanium dioxide overlayer and to ion diffusion through the surrounding tissues.

Connective Tissue