A Cole phantom for EIT.

Abstract

A phantom was designed for testing and comparing multifrequency EIT data collection systems. The phantom simulates a cylinder of homogeneous conductor with 16 drive and 16 receive electrodes interleaved. Combinations of resistors and capacitors were used to simulate the complex impedance, Z*, of a typical tissue in the frequency range 8-2048 kHz obeying the Cole equation Z* = Z infinity + (Z0 - Z infinity)/[1 + (if/fc)(1- alpha )] where Z* is the complex impedance at frequency f, Z0 and Z infinity are the limiting values of impedance at low and high frequencies, fc is the characteristic frequency and alpha is a constant. A practical phantom was then constructed on which four different sets of spectroscopic parameters could be selected: (i) alpha = 0.20, fc = 150 kHz, Z0/Z infinity = 3.31; (ii) alpha = 0, fc = 273 kHz, Z0/Z infinity = 2.64; (iii) alpha = 0, fc = 71.1 kHz, Z0/Z infinity = 1.36; and (iv) Z0/Z infinity = 1.00 with no dispersion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Griffiths. 1995. A Cole phantom for EIT.. https://doi.org/10.1088/0967-3334%2F16%2F3a%2F003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gastroesophageal reflux and respiratory phenomena in infants: status of the intraluminal impedance technique.

BACKGROUND: The coincidence of recurrent respiratory symptoms and gastroesophageal reflux (GER) is a well-known phenomenon in infants. Twenty-four-hour pH metry is the presumed gold standard of diagnostic tools for this symptom complex, but with this method, only acid (pH <4) and alkaline (pH >7) GER can be detected. Gastroesophageal reflux with an esophageal pH in the physiological range (pH 5-6.8) may represent many cases of clinically relevant GER unrecognized by pH metry. In this study the intraluminal multiple electrical impedance (IMP) procedure for complete registration of GER was compared with pH metry for its diagnostic value in the presence of respiratory symptoms. METHODS: Twenty-two infants with recurrent regurgitation or pulmonary problems were investigated simultaneously with IMP, pH metry, and polygraphy during two feeding periods. Heart rate, oxygen saturation, sleep states, and oronasal flow were recorded, among other parameters. RESULTS: Three hundred sixty-four occurrences of GER were detected by IMP; only 11.4% had a pH less than 4 and were therefore recognized by pH metry. Three hundred twelve (84.8%) occurrences were associated with breathing abnormalities, and 11.9% of these were detected by pH metry. Nineteen instances were accompanied by a decrease of oxygen saturation of more than 10% of the initial value. Only three (15.8%) of these had a pH less than 4. The remaining 16 reflux episodes were recognized by IMP only. After software-aided preselection, 165 instances of apnea were visually validated, 49 of which were accompanied by GER. Thirty-eight (77.6%) of these were exclusively recorded by IMP. CONCLUSIONS: The use of pH metry alone cannot detect most GER incidents accompanied by respiratory symptoms and therefore does not appear to be suitable for this approach. The pH-independent IMP technique promises to be a reliable tool for presumably GER-associated respiratory symptoms.

Electric Impedance

Preamplifier with a second-order high-pass filtering characteristic.

A new preamplifier for suppressing low-frequency interference is presented. The proposed preamplifier, with its front end being implemented by an instrumentation amplifier, enjoys the following advantages: differential high-pass filtering, high input impedance, high common--mode rejection ratio and low passive sensitivity. This circuit can be realized with commercial operational amplifiers with enough phase margin, or fabricated in a chip for practical measurement of physiological signals.

Electric Impedance

The excitation of NMR transitions by the current in a sample and the proposals for its detection.

A new magnetic resonance technique for investigating conducting samples is described. NMR transitions are excited by the magnetic field of alternating current which flows across the sample. The dissipation of the energy caused by NMR transitions results in a change of the impedance of the sample. The NMR signal is detected as an associated change of the voltage drop across a sample while passing through the resonance region. It is predicted that the resonance can be detected by state-of-the-art low-noise superconducting quantum interference device (SQUID)-based NMR spectrometers. The method is believed to be useful for investigations of small-volume samples which are inaccessible by other NMR techniques.

Electric Impedance