Search PubMed⌕ Search

PubMed · 8524561

Detecting progressive visual field loss.

Abstract

Involvement in shared care projects requires the optometrist to make a series of decisions one of which is an assessment of the visual field data to see if there has been any progression. To aid the optometrist in making this decision, the relationship between inter-test variability in the visual field and extent of loss has been established for the Henson CFS2000 perimeter. In this study, visual field data were collected, with a supra-threshold strategy, from 174 eyes (89 patients) over a period of 2 years, there being a total of 595 visual field records. The sample included patients with both normal and glaucomatous visual fields. The results show that analysis based upon the number of stimuli missed at 5 or more dB above the threshold estimate reveals an increasing variability with extent of loss. These data can be used by optometrists to establish the significance of any change in the number of missed stimuli from one visit to the next.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D B Henson, M N Darling. 1995. Detecting progressive visual field loss.. https://pubmed.ncbi.nlm.nih.gov/8524561/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗