Pseudohyperphosphatemia.

Abstract

OBJECTIVE: To review instances of spurious elevation of inorganic phosphate measurements due to interference with analytical methods. METHODS: SElective literature review. RESULTS: Depending on the method used to measure inorganic phosphate, several factors have been reported to produce spurious elevations, including paraproteinemia, hyperlipidemia, hemolysis, and hyperbilirubinemia. Of these, paraproteinemia is probably the commonest. CONCLUSION: Both clinical biochemists and clinicians should be aware of the phenomenon of pseudohyperphosphatemia. Clinically unexplained persistent hyperphosphatemia should initiate a search for potential causes of pseudohypophosphatemia, especially paraproteinemia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A J Larner. 1995. Pseudohyperphosphatemia.. https://doi.org/10.1016/0009-9120(95)00013-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Capillary electrophoresis with laser-induced native fluorescence detection for profiling body fluids.

Laser-induced native fluorescence detection with a KrF excimer laser (lambda=248 nm) was used to investigate the capillary electrophoretic (CE) profiles of human urine, saliva and serum without the need for sample derivatization. All separations were carried out in sodium phosphate and/or sodium tetraborate buffers at alkaline pH in a 50-microm I.D. capillary. Sodium dodecyl sulfate was added to the buffer for micellar electrokinetic chromatography (MEKC) analysis of human urine. Although inherently a pulsed source, the KrF excimer laser was operated at a high pulse repetition rate of 553, 1001 or 2009 Hz to simulate a continuous wave excitation source. Detection limits were found to vary with pulse rate, as expected, in proportion to average excitation power. The following detection limits (3sigma) were determined in free solution CE: tryptophan, 4 nM; conalbumin, 10 nM; alpha-lactalbumin, 30 nM. Detection limits for indole-based compounds and catecholamine urinary metabolites under MEKC separation conditions were in the range 7-170 nM.

Blood Chemical Analysis

Enhancement of footwear impressions in blood.

Methods for chemical enhancement of footwear impressions in blood were compared in order to make a separation between utilization at the scene of crime, the local (regional) police laboratory and the Dutch Forensic Science Laboratory (DFSL).

Blood Chemical Analysis