Search PubMedSearch

PubMed · 8507805

[Algorithm for calibrating eye movements].

Abstract

A mathematical model and the corresponding computer program based on an algorithm for calibration of eye movements are described. The latter is used to represent and analyse eye movements on a monitor screen using the EYE/HAND software, with the aid of which movements of eye and hand can be represented either simultaneously or separately. Demands on the rate of data acquisition and representation of the curves (real-time monitoring) are satisfied. Calibration is based on vector transformation of the digitised analog values to monitor coordinates. The parameters of the transformation algorithm are determined by fixation of the eye movements to freely selectable monitor screen markers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Hofmann, P Weber. 1993. [Algorithm for calibrating eye movements].. https://pubmed.ncbi.nlm.nih.gov/8507805/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

External radiation therapy boost to the vaginal vault: feasibility of intracavitary dosimetry using a commercial diode system.

PURPOSE: An overall check of the whole dosimetry procedure by intracavitary in vivo dosimetry, using n-type silicon diode dosimeter, was performed during 6-MV x-ray irradiation of the vaginal vault. The dose delivered to the isocenter by all treatment fields was evaluated. METHODS AND MATERIALS: The diode dosimeter was calibrated against an ion chamber and tissue maximum ratio, field size factor, SSD factor, and temperature dependence studies were performed. Diode system accuracy, linearity, and reproducibility were also tested. Patients' dose data were collected and comparision was made with respect to treatment-planning dose calculations. Ten patients with cervical cancer and endometrial cancer were treated with surgery and irradiation. During the boost to the vaginal vault, a diode was inserted by an intravaginal device and the vaginal vault was the isocenter of the four fields. The field size generally was not larger than 10 x 10 cm2. RESULTS: Diode-measured "tissue maximum ratio" agreed to within 1% with those measured with an ion chamber in field from 7 x 7 to 10 x 10 cm2. The diode also exhibited a temperature dependence of 0.1% degrees C(-1). For 10 patients treated with a 6-MV beam, the agreement with treatment-planning dose calculations was shown to be better than +/-4%. CONCLUSION: The good accuracy and reproducibility of the diode system shows that determination of the dose at isocenter, for patients treated in the pelvic region, can be performed with n-type diodes accurately. On the other hand, in the vaginal vault boost, external-beam radiotherapy is delivered accurately and in vivo dosimetry is really not indicated.

Calibration

Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy.

PURPOSE: The irradiation system and biophysical characteristics of carbon beams are examined regarding radiation therapy. METHODS AND MATERIALS: An irradiation system was developed for heavy-ion radiotherapy. Wobbler magnets and a scatterer were used for flattening the radiation field. A patient-positioning system using X ray and image intensifiers was also installed in the irradiation system. The depth-dose distributions of the carbon beams were modified to make a spread-out Bragg peak, which was designed based on the biophysical characteristics of monoenergetic beams. A dosimetry system for heavy-ion radiotherapy was established to deliver heavy-ion doses safely to the patients according to the treatment planning. A carbon beam of 80 keV/microm in the spread-out Bragg peak was found to be equivalent in biological responses to the neutron beam that is produced at cyclotron facility in National Institute Radiological Sciences (NIRS) by bombarding 30-MeV deuteron beam on beryllium target. The fractionation schedule of the NIRS neutron therapy was adapted for the first clinical trials using carbon beams. RESULTS: Carbon beams, 290, 350, and 400 MeV/u, were used for a clinical trial from June of 1994. Over 300 patients have already been treated by this irradiation system by the end of 1997.

Calibration

Detection of the presence of soya protein in milk powder by sodium dodecyl sulfate capillary electrophoresis.

Two different commercial kits for sodium dodecyl sulfate capillary electrophoresis (SDS-CE) were evaluated for the detection of the presence of soya protein in milk powder. The results obtained showed that SDS-CE allowed the separation of the basic subunits of glycinin and the alpha and alpha' subunits of beta-conglycinin from the main milk protein peaks. However, a detection limit lower than 10% (w/w) of soya protein in total protein could not be achieved. The use of a tetraborate-EDTA sample treatment minimized interferences from milk proteins, allowing the detection of at least 1% (w/w) of soya protein in total protein. The addition of soya protein hydrolysates could not be determined using SDS-CE.

Calibration