Search PubMed⌕ Search

PubMed · 8475813

Titanium Riechert head ring for MR stereotaxy. Technical note.

Abstract

Magnetic Resonance has become the preferred neuro-imaging modality. To fully take advantage of the high anatomical resolution the Riechert stereotactic system was adapted for use in Magnetic Resonance Stereotaxy. The head ring which until recently was made of an aluminum alloy has been replaced by an unsegmented head ring of pure titanium without changing the dimensions and fixation mode. No significant misregistration due to eddy currents has been noticed. Minor distortion induced by the titanium head ring can be corrected mathematically. Thus the geometric information is limited only by the pixel resolution of the MR image.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C B Ostertag, L R Schad, R Koch, R Maier, B Wowra. 1993. Titanium Riechert head ring for MR stereotaxy. Technical note.. https://doi.org/10.1007/bf01405188

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗