A static dynamometer measuring multidirectional torques exerted simultaneously at the hip and knee.

Abstract

The function of a static dynamometer measuring torques exerted simultaneously in the different anatomical planes of the hip (flexion-extension, abduction-adduction and internal-external rotation) and knee (flexion-extension) is described. Muscular torques were calculated in real time using a desktop computer from measurements of orthogonal forces applied at two locations and the lever arm values measured in each subject. The reliability of the force transducers was explored by examining their output, using calibrated weights, on three different days. The results were identical over this period of time, indicating that the transducers are highly reliable. A mechanical simulator of a lower limb was constructed to generate specific or combined torques of known values at the hip and knee. The torques measured by the dynamometer were found to be highly concordant with the known torques applied by the simulator, indicating that the torque measurements were valid. The usefulness of the dynamometer is demonstrated by evaluating the activity of the rectus femoris and biceps femoris muscles during static efforts exerted in various directions at the hip. In addition, the mechanical action of biarticular muscles at the hip was evaluated by quantification of hip torques during efforts exerted at the knee. From these results, it has been concluded that the present biarticular and multidirectional dynamometer is a valid, reliable and precise instrument that may prove to be useful in evaluating the muscular function of the lower limb.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Bourbonnais, P Duval, D Gravel, C Steele, J Gauthier, J Filiatrault, M Goyette, B Arsenault. 1993. A static dynamometer measuring multidirectional torques exerted simultaneously at the hip and knee.. https://doi.org/10.1016/0021-9290(93)90366-m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Under the microscope: single molecule symposium at the University of Michigan, 2006.

In recent years, a revolution has occurred in the basic sciences, which exploits novel single molecule detection and manipulation tools to track and analyze biopolymers in unprecedented detail. A recent Gordon Research Conference style meeting, hosted by the University of Michigan, highlighted current status and future perspectives of this rising field as researchers begin to integrate it with mainstream biology and nanotechnology.

Biophysics↗

Red antenna states of photosystem I from cyanobacteria Synechocystis PCC 6803 and Thermosynechococcus elongatus: single-complex spectroscopy and spectral hole-burning study.

Hole-burning and single photosynthetic complex spectroscopy were used to study the excitonic structure and excitation energy-transfer processes of cyanobacterial trimeric Photosystem I (PS I) complexes from Synechocystis PCC 6803 and Thermosynechococcus elongatus at low temperatures. It was shown that individual PS I complexes of Synechocystis PCC 6803 (which have two red antenna states, i.e., C706 and C714) reveal only a broad structureless fluorescence band with a maximum near 720 nm, indicating strong electron-phonon coupling for the lowest energy C714 red state. The absence of zero-phonon lines (ZPLs) belonging to the C706 red state in the emission spectra of individual PS I complexes from Synechocystis PCC 6803 suggests that the C706 and C714 red antenna states of Synechocystis PCC 6803 are connected by efficient energy transfer with a characteristic transfer time of approximately 5 ps. This finding is in agreement with spectral hole-burning data obtained for bulk samples of Synechocystis PCC 6803. The importance of comparing the results of ensemble (spectral hole burning) and single-complex measurements was demonstrated. The presence of narrow ZPLs near 710 nm in addition to the broad fluorescence band at approximately 730 nm in Thermosynechococcus elongatus (Jelezko et al. J. Phys. Chem. B 2000, 104, 8093-8096) has been confirmed. We also demonstrate that high-quality samples obtained by dissolving crystals of PS I of Thermosynechococcus elongatus exhibit stronger absorption in the red antenna region than any samples studied so far by us and other groups.

Biophysics↗