Visual lung-sound characterization by time-expanded wave-form analysis.

Abstract

To characterize lung sounds objectively, we examined, by means of time-amplitude plots, selected tape recordings of auscultatory phenomena considered by six observers to be typical of those in a standard classification. Normal lung sounds could not consistently be visually distinguished from adventitious sounds at conventional chart recorder speeds of 100 mm per second or less, but the differentiation was easily achieved when the time scale of the plots was raised to 800 mm per second. When discontinuous sounds (rales, crackles or crepitations) were heard clinically, the time-expanded wave forms showed intermittent "discontinuous" deflections usually less than 10 msec in duration. When continuous sounds (rhonchi or wheezes) were heard, the deflections were usually more than 250 msec. Time-expanded wave form analysis provides reproducible visual displays that allow documentation of the differentiating features of lung sounds and enhances the diagnostic utility of the sounds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Murphy, S K Holford, W C Knowler. 1977-04-28. Visual lung-sound characterization by time-expanded wave-form analysis.. https://doi.org/10.1056/nejm197704282961704

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transmission of lung sounds through light clothing.

BACKGROUND: Doctors are exhorted to always place the stethoscope directly on the skin and never to auscultate through clothing. Nevertheless, casual observation reveals that doctors and even pulmonologists often violate this principle. OBJECTIVES: This study was designed to evaluate the sensitivity of two common stethoscopes when used through clothing. METHODS: Littmann Classic and Littmann Master Cardiology stethoscopes were studied under conditions of light (60-100 g), medium (240 g) and heavy (555 g) force when placed on a lung sound test platform with one or two layers of cloth (T-shirt material and flannel) interposed between the stethoscope and the test surface. The test platform was designed to mimic the acoustic and mechanical properties of the chest wall and was driven by amplified white noise. The recorded amplitude spectra were compared over a range of 150-1,000 Hz. RESULTS: Compared to the sensitivity on a bare test platform surface, either fabric in single or double layers attenuated the sounds by a mean of 5-18 dB under light pressure. This attenuation was nearly abolished by the addition of either medium or heavy force on the stethoscope head. CONCLUSIONS: The deleterious effect of one or two layers of indoor clothing on lung sounds acquired through a stethoscope can be negated by force on the stethoscope head making effective auscultation possible. Nevertheless, auscultation through clothing remains problematic due to the hindrance to inspection and percussion and the risk of acoustic artifacts caused by clothing.

Auscultation↗

A huge obstructive myxoma located in the right heart without causing any symptom.

Cardiac myxoma is unusual and mostly located in left atrium. Although it is a benign tumor of the heart, it may cause life-threatening cardiac problems like valvular obstruction, systemic or pulmonary massive embolism, infection, arrhythmia, malignance. We report a huge cardiac myxoma originated from right atrium. It was moving between right atrium and ventricle without any symptoms.

Auscultation↗