Overlapping section coverage in multisection imaging.

Abstract

A method is proposed in which the section position for two-dimensional Fourier transform multisection imaging is advanced from one phase-encoding step to the next, so that information is sampled continuously over the total volume under observation. This "ramp scan" technique allows reconstruction of images from any arbitrary position within the sampled volume. The imaging properties depend strongly on the order of distribution of phase-encoding steps to the different section positions. In practice, images are reconstructed at each nominal position of a multisection experiment, plus at each position halfway between sections. The volume under study is thus represented by overlapping sections. The gaps between sections that arise in conventional multisection imaging--even with optimized pulse shapes--are thus avoided. This approach is applicable not only to conventional spin-echo imaging but to other techniques such as RARE (rapid acquisition with relaxation enhancement) and gradient-echo and echo-planar imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Hennig. Overlapping section coverage in multisection imaging.. https://doi.org/10.1002/jmri.1880030219

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Two-way conversation with a mass spectrometer: nondestructive interactive mass spectrometry.

Most mass spectrometers employ destructive detection, so that it is necessary to repeat an experiment in order to vary even one parameter. In contrast, Fourier transform ion cyclotron resonance mass spectrometry offers nondestructive detection, so that ions remain available for further manipulation and redetection. Here, we show for the first time how to perform mass spectrometry interactively. Following each elementary experimental stage, such as ion generation, isolation, dissociation, or detection, the operator is free to choose and tailor the next stage without creating a fresh supply of ions. For example, we can test the effect of varying one parameter over several values without having to repeat the entire experimental event sequence each time, much like varying one letter or word in a sentence without having to rewrite the whole sentence. Such interactive control promises to speed development of complex experimental event sequences, as for optimizing the sequencing and structural analysis of tiny amounts (e.g., femtomoles or less) of biomacromolecules (peptides, nucleic acids, oligosaccharides).

Fourier Analysis

Small-angle neutron scattering by a strongly denatured protein: analysis using random polymer theory.

Small-angle neutron scattering profiles are presented from phosphoglycerate kinase, in the native form and strongly denatured in 4 M guanidinium chloride (GdnHCl) solution. The data are interpreted using a model in which the excess scattering density associated with the protein is represented as a finite freely jointed chain of spheres. The similarity of the model-derived scattering function to experiment increases asymptotically with the number of spheres. The improvement of the fit obtained with more than approximately 200 spheres (i.e., two residues per sphere) is insignificant. The effects of finite size of the scattering units and of scattering length variation along the polypeptide chain are examined. Improved agreement with experiment is obtained when these effects are taken into account. A method for rapid calculation of the scattering profile of a full, all-atom configuration is examined. It is found that a representation of the chain containing two scattering units per residue, placed at the backbone and side-chain scattering length centroids, reproduces the full, all-atom profile to within 2%.

Fourier Analysis

Three-dimensional motional stabilization in the trapping field of an open-ended trapped-ion cell: application to the remeasurement experiment in Fourier transform ion cyclotron resonance mass spectrometry.

Three-dimensional motional stabilization of radial trajectories of low-mass organic ions in an open cell using only a dc trapping field is applied to the FT-ICR remeasurement experiment. More than 300 remeasurement cycles are observed with 99.59% remeasurement efficiency for benzene (m/z 78) using a high-pressure helium buffer gas. The enhancement in remeasurement efficiency is due to collisional stabilization of the guiding center of ion motion by dynamic motional averaging in the axial position-dependent radial electric field. Such dc-induced radial stabilization is in contrast to the stability produced by application of radio frequency fields characteristic of quadrupolar axialization or rf-only mode operation. The same effect is produced because ions experience a radial "pseudopotential" during axial oscillation as in time-varying fields. Trajectory simulations for ions oscillating in an open cell trapping well above a z-amplitude critical threshold energy of 0.60 eV (in a potential well of 0.84 V) indicate that radially stabilized trapping motion is achieved because the outward-directed radial electric field existing near the cell center line is compensated by an opposing inward-directed radial electric field at extended z-amplitude. Sufficient axial kinetic energy permits ion penetration into the inward-directed radial electric field regions, enabling > 50% residence time of each trapping oscillation period in regions inducing radial stability, thereby inhibiting magnetron radius growth. A high-pressure, low-mass buffer gas such as helium provides the requisite increase in the axial amplitude of the ion cloud, similar to the mechanism observed for axial excitation of low-mass ions observed in collision-induced dissociation. The result is radial stability at high pressure, even after multiple remeasurement cycles. An optimized excitation radius of 12.5% of the cell radius yields maximum remeasurement efficiency with a 500 ms relaxation delay between excitation events. Summed signal intensity decreases with increased trap potential due to the greater radial electric field and reduced axial expansion of the ion cloud and also decreases with buffer gas mass in response to greater radial scattering.

Fourier Analysis