Computer-generated orthoses. A review.

Abstract

It is obvious with the various casting techniques used in the study that the ease with which individuals adjust to the fashionette orthotic makes it a desirable device. It is tolerated well with higher-heeled shoes and shoes that are used more for fashion purposes. Future studies need to assess the degree of control compared with the type of deformity and the type of symptoms the patient has. These types of devices may be sufficient to minimize stress on a given deformity, such as a neuroma, but may not be sufficient enough to eliminate the need for the removal of the neuroma. Recurrence of the neuroma after it has been resected and the patient prescribed a fashionette orthosis also needs to be assessed. A neuroma is one example of a type of deformity that needs to be controlled and evaluated with regard to cause and response to orthotic therapy. Abnormal tylomas and pressure lesions need to be assessed on a symptomatic basis for their control with the different types of devices and the pathomechanic causing the pressure. This study indicates that milled orthoses are tolerated better than pressed orthoses. Milled orthoses require less adjustment and the adjustment is tolerated better, regardless of the casting position. The degree of position control had some variations. When comparing the pressed and the milled functional orthoses, there is a more rapid adjustment with the milled type of orthoses. This suggests that possibly the milled orthoses have less alteration in shape and loss of contour from the direct milling and the digitizing process compared with the pressing techniques. The long-term effect of pressing compared with milled orthotics was not assessed during this study with regard to fluid distortion of the polypropylene over time. The fluid nature has a tendency to suffer a loss of contour and progressive loss of function. The milled process theoretically has less change in the contour with the passage of time, although this needs to be assessed in further studies. Possibly, the fluid nature of the orthosis can be assessed by determining how soon the symptoms return between adjustments. Posting surfaces tend to wear over a period of time and distort with the fluid nature. The posting can break down from the type of material from which it is made. A model of assessment for future studies may be to check the duration of when heel spur types of symptoms or postural complex types of symptoms, such as knee pain or lower back pain, recur.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Grumbine. 1993. Computer-generated orthoses. A review.. https://pubmed.ncbi.nlm.nih.gov/8364842/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimization of a jet-propelled particle injection system for the uniform transdermal delivery of drug/vaccine.

A jet-propelled particle injection system, the biolistics, has been developed and employed to accelerate micro-particles for transdermal drug delivery. We have examined a prototype biolistic device employing a converging-diverging supersonic nozzle (CDSN), and found that the micro-particles were delivered with a wide velocity range (200-800 m/s) and spatial distribution. To provide a controllable system for transdermal drug delivery, we present a contoured shock-tube (CST) concept and its embodiment device. The CST configuration utilizes a quasi-steady, quasi-one dimensional and shock-free supersonic flow to deliver the micro-particles with an almost uniform velocity (the mean velocity and the standard deviation, 699 +/- 4.7 m/s) and spatial distribution. The transient gas and particle dynamics in both prototype devices are interrogated with the validated computational fluid dynamics (CFD) approach. The predicted results for static pressure and Mach number histories, gas flow structures, particle velocity distributions and gas-particle interactions are presented and interpreted. The implications for clinical uses are discussed.

Computer-Aided Design↗

A stand-alone peristaltic micropump based on piezoelectric actuation.

Despite significant efforts to develop micropumps, cumbersome driving equipment means that the design of portable micropumps remains a challenge. This study presents a stand-alone micropump system, which includes a peristaltic micropump based on piezoelectric actuation and a driving circuit. This battery-based driving circuit comprises a 12 V battery, an ATmega 8535 microprocessor, a 12 V-to-180 V DC to DC converter using transformerless technology, three differential amplifiers, an IC 7805, a phase controller, an A/D converter, a keyboard and an LCD module. The system can produce step-function signals with voltages of up to 228 V(pp) and frequencies ranging from 10 Hz to 100 kHz, as the inputs for the pump. It is portable and programmable with the package size of 22 x 12.8 x 9 cm. Additionally, this proposed system is used to design the driving signals of the pump which are 3-, 4, and 6-phase actuation sequences. This work performs the circuit testing and fluid pumping, and demonstrates the effects of actuation sequences on pump performance in terms of the dynamic behavior of the diaphragm, flow rates, back pressure and power consumption of the system. The experimental results show that the pump excited by the 6-phase sequence results in better performance compared with the 3- and 4-phase sequences, and produces a maximum flow rate of 36.8 microl/min and a maximum back pressure of 520 Pa with deionized water at 100 V (pp) and 700 Hz.

Computer-Aided Design↗

Novel transmit protection scheme for ultrasound systems.

The problem of protecting or isolating extremely sensitive receive circuitry from high-voltage transmit circuitry is commonly addressed through the use of diode bridges, transformers, or high-voltage switches, which prove to be prohibitively expensive, bulky, and power consuming for use in portable, low-cost, battery-powered systems. These approaches also compound the interconnect difficulties associated with two-dimensional (2-D) transducer arrays. In this paper we present a novel transmit protection scheme that allows compact MOSFET shunting devices to be brought on-chip within each receive channel implemented in a standard CMOS integrated circuit process. During transmit, the high voltage transmit pulse is driven onto the common connection of the transducer array and the on-chip MOSFET devices shunt the current to ground. During receive, these devices are turned off, the common connection of the transducer array is shunted to ground, and the received echo can be detected as usual. The transmit protection scheme was experimentally shown to shunt a 16 mA peak current resulting from the equivalent of a 100-V, 25-ns-risetime transmit pulse through a 4 pF transducer element. The scheme was also incorporated into a prototype 1024-channel, low-cost, ultrasound system successfully used to form pulse echo images.

Computer-Aided Design↗