Fluorescence spectroscopy.

Abstract

This chapter has introduced the theory of fluorescence, and briefly shown that it is a technique with many wide and varied applications in biochemistry. It has the overall advantage of being able to carry out measurements on small amounts of sample in solution, often revealing important information concerning the structure and dynamics of these systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P G Varley. 1994. Fluorescence spectroscopy.. https://doi.org/10.1385/0-89603-232-9%3A203

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of picomolar concentrations of metal ions using fluorescence anisotropy: biosensing with a "reagentless" enzyme transducer.

Because of their high affinity and selectivity, metalloproteins can be used as transducers in novel sensors, i.e., biosensors, for the determination of trace levels of metal ions in solution. Here, we exploit carbonic anhydrase to determine picomolar to nanomolar concentrations of free transition metal ions by fluorescence anisotropy (polarization) in a reagentless format. Carbonic anhydrase variants engineered with a cysteine replacing a residue chosen near the active site (F131C and H64C) were covalently labeled with derivatives of benzoxadiazole sulfonamide. These labeled variants exhibited changes in anisotropy up to 0.07 upon binding free Cu(II), Co(II), and Zn(II) with apparent Kd's close to the values observed with wild-type apocarbonic anhydrase. The covalent attachment of the label has significant advantages over noncovalent labels we have described previously. Furthermore, the metal ion-dependent anisotropy changes were predictable using simple theory. The results demonstrate that free transition metal ions can be determined at trace levels in aqueous solution using inexpensive instruments.

Anisotropy

High-frequency, spin-label EPR of nonaxial lipid ordering and motion in cholesterol-containing membranes.

The EPR spectra of spin-labeled lipid chains in fully hydrated bilayer membranes of dimyristoyl phosphatidylcholine containing 40 mol % of cholesterol have been studied in the liquid-ordered phase at a microwave radiation frequency of 94 GHz. At such high field strengths, the spectra should be optimally sensitive to lateral chain ordering that is expected in the formation of in-plane domains. The high-field EPR spectra from random dispersions of the cholesterol-containing membranes display very little axial averaging of the nitroxide g-tensor anisotropy for lipids spin labeled toward the carboxyl end of the sn-2 chain (down to the 8-C atom). For these positions of labeling, anisotropic 14N-hyperfine splittings are resolved in the gzz and gyy regions of the nonaxial EPR spectra. For positions of labeling further down the lipid chain, toward the terminal methyl group, the axial averaging of the spectral features systematically increases and is complete at the 14-C atom position. Concomitantly, the time-averaged element of the 14N-hyperfine tensor decreases, indicating that the axial rotation at the terminal methyl end of the chains arises from correlated torsional motions about the bonds of the chain backbone, the dynamics of which also give rise to a differential line broadening of the 14N-hyperfine manifolds in the gzz region of the spectrum. These results provide an indication of the way in which lateral ordering of lipid chains in membranes is induced by cholesterol.

Anisotropy

Short-term memory for reaching to visual targets: psychophysical evidence for body-centered reference frames.

Pointing to a remembered visual target involves the transformation of visual information into an appropriate motor output, with a passage through short-term memory storage. In an attempt to identify the reference frames used to represent the target position during the memory period, we measured errors in pointing to remembered three-dimensional (3D) targets. Subjects pointed after a fixed delay to remembered targets distributed within a 22 mm radius volume. Conditions varied in terms of lighting (dim light or total darkness), delay duration (0.5, 5.0, and 8.0 sec), effector hand (left or right), and workspace location. Pointing errors were quantified by 3D constant and variable errors and by a novel measure of local distortion in the mapping from target to endpoint positions. The orientation of variable errors differed significantly between light and dark conditions. Increasing the memory delay in darkness evoked a reorientation of variable errors, whereas in the light, the viewer-centered variability changed only in magnitude. Local distortion measurements revealed an anisotropic contraction of endpoint positions toward an "average" response along an axis that points between the eyes and the effector arm. This local contraction was present in both lighting conditions. The magnitude of the contraction remained constant for the two memory delays in the light but increased significantly for the longer delays in darkness. These data argue for the separate storage of distance and direction information within short-term memory, in a reference frame tied to the eyes and the effector arm.

Anisotropy