Search PubMed⌕ Search

PubMed · 8283

Pleural fluid pH in parapneumonic effusions.

Abstract

The pH and carbon dioxide tension were measured in 24 consecutive parapneumonic effusions, along with the leukocyte count, leukocytic differential count, and levels of glucose and protein. Three categories of parapneumonic effusions were characterized: (1) empyemas; (2) benign (nonloculated) effusions; and (3) loculated effusions. A pH greater than 7.30 was present in all ten benign effusions, and spontaneous resolution occurred in each case. All ten empyemas and the four loculated effusions had a pH less than 7.30. All four loculated effusions required drainage with a chest tube for resolution. The pH of the pleural fluid alone separated the empyemas and loculated effusions from benign effusions. The early separation of parapneumonic effusions on the basis of the pleural fluid appears useful. If the pH is greater than 7.30, a benign effusion is present, and spontaneous resolution is likely. If the pH is less than 7.30, loculation of the pleural space may occur regardless of whether the effusion fulfills the criteria for empyema.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Potts, D C Levin, S A Sahn. 1976. Pleural fluid pH in parapneumonic effusions.. https://doi.org/10.1378/chest.70.3.328

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗