Search PubMed⌕ Search

PubMed · 8280313

An isoelastic prosthesis using a new composite material.

Abstract

A new particulate composite material has been assessed with regard to the design of an 'isoelastic' or 'modulus matched' hip prosthesis. Three different prototype designs were assessed, each of which consisted of a femoral component made from the composite material, attached to a metal ball via a metal 'spike' insert. The prototypes varied in terms of the detailed shape of the spike, which was modified in the light of photoelastic stress analysis, so as to produce a more acceptable stress distribution to the composite material in the proximal region. Prototypes were made by hand moulding and by transfer moulding; both methods produced defects of various kinds. Simulation tests were conducted using a model of the proximal femur constructed from glass fibre composite, cyclically loaded in a servo-hydraulic testing machine. Though some difficulties were experienced with defective mouldings, especially for the transfer moulding process, a clear improvement was demonstrated for the final (Mark III) design. The fatigue endurance of this prototype was similar to that of conventional metal prostheses tested under similar conditions. Fatigue crack propagation tests were carried out on samples of the composite material to establish its propagation threshold. These results were combined with a finite element stress analysis and fracture mechanics theory to estimate the critical crack length for fatigue in this prosthesis. It was thus possible to specify the maximum safe size of defect that could be tolerated in use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Taylor, C Martin, B Cornelis, M E Jones. 1993. An isoelastic prosthesis using a new composite material.. https://doi.org/10.1243/pime_proc_1993_207_280_02

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a 3D cell culture system for investigating cell interactions with electrospun fibers.

There are many variables to be considered in studying how cells interact with 3D scaffolds used in tissue engineering. In this study we investigated the influence of the fiber diameter and interfiber spaces of 3D electrospun fiber scaffolds on the behavior of human dermal fibroblasts. Fibers of two dissimilar model materials, polystyrene and poly-L-lactic acid, with a broad range of diameters were constructed in a specifically developed 3D cell culture system. When fibroblasts were introduced to freestanding fibers, and encouraged to "walk the plank," a minimum fiber diameter of 10 microm was observed for cell adhesion and migration, irrespective of fiber material chemistry. A distance between fibers of up to 200 microm was also observed to be the maximum gap that could be bridged by cell aggregates--a behavior not seen in conventional 2D culture. This approach has identified some basic micro-architectural parameters for electrospun scaffold design and some key differences in fibroblast growth in 3D. We suggest the findings will be of value for optimizing the integration of cells in these scaffolds for skin tissue engineering.

Biocompatible Materials↗

Improved catalytic properties of immobilized lipases by the presence of very low concentrations of detergents in the reaction medium.

The addition of a very small concentration of a detergent (in many instances under the critical micellar concentration (cmc)) has been found to greatly increase the activity of immobilized lipases, using those from Pseudomonas fluorescens (PFL) and Candida antarctica (isoform B) as model enzymes. However, the detergents may also have a negative effect on enzyme activity; in fact, for all enzyme preparations and substrates the activity/detergent concentration curve reached a maximum value and started to decrease, in many instances even under the initial value. The concentration and nature of the detergent (SDS, CTAB, Triton X-100, or X-45) that permitted the maximum hyperactivation was different depending on the substrate. The best hyperactivation values promoted by the presence of detergent were over a 20-fold factor. The presence of detergents permitted the inhibition of lipases by irreversible covalent inhibitors (e.g., 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride) (AEBSF) while the enzyme, in the absence of detergent, is not inhibited by these irreversible inhibitors. This suggested that the main effect of the detergents is to shift the conformational equilibrium of lipases toward the open form. Moreover, the presence of detergents also permitted to improve the enantioselectivity exhibited by the immobilized lipases in some cases. For example, the enantioselectivity of PFL-glyoxyl agarose increased from 40 to more than 100 in the hydrolysis of (+/-)-2-hydroxy-4-phenylbutyric acid ethyl ester by using 0.1% CTAB.

Biocompatible Materials↗

Development of wollastonite-poly(ethylmethacrylate co-vinylpyrrolidone) based materials for multifunctional devices.

The manufacturing of a composite made of a synthetic bioactive ceramic, pseudowollastonite (psW), and a bioresorbable copolymer ethylmethacrylate-vinylpyrrolidone (EMA/VP) is presented in this article. psW porous blocks were produced by dipping an open porous polyurethane foam in a psW containing slurry. A 40/60 wt % EMA/VP monomers mixture was poured on the blocks, and free radical polymerization initiated by azobis(isobutyronitrile) at 50 degrees C. Disks of 1 mm height were obtained by cutting the composite with a diamond saw, and bioresorption and bioactivity of the specimens were tested by immersion of the disks into SBF. A ceramic/polymer weight ratio of 72/28, greater than the usually achievable ratio by polymeric solidification of slurries of monomers charged with a powdered solid component, has been obtained. The system is bioactive and does not change the pH of the medium during the degradation test.

Biocompatible Materials↗