Search PubMed⌕ Search

PubMed · 8273340

Posterior tibial tendon dysfunction.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T S Woll. 1993. Posterior tibial tendon dysfunction.. https://pubmed.ncbi.nlm.nih.gov/8273340/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy of Ottawa ankle rules to exclude fractures of the ankle and mid-foot: systematic review.

OBJECTIVE: To summarise the evidence on accuracy of the Ottawa ankle rules, a decision aid for excluding fractures of the ankle and mid-foot. DESIGN: Systematic review. DATA SOURCES: Electronic databases, reference lists of included studies, and experts. REVIEW METHODS: Data were extracted on the study population, the type of Ottawa ankle rules used, and methods. Sensitivities, but not specificities, were pooled using the bootstrap after inspection of the receiver operating characteristics plot. Negative likelihood ratios were pooled for several subgroups, correcting for four main methodological threats to validity. RESULTS: 32 studies met the inclusion criteria and 27 studies reporting on 15 581 patients were used for meta-analysis. The pooled negative likelihood ratios for the ankle and mid-foot were 0.08 (95% confidence interval 0.03 to 0.18) and 0.08 (0.03 to 0.20), respectively. The pooled negative likelihood ratio for both regions in children was 0.07 (0.03 to 0.18). Applying these ratios to a 15% prevalence of fracture gave a less than 1.4% probability of actual fracture in these subgroups. CONCLUSIONS: Evidence supports the Ottawa ankle rules as an accurate instrument for excluding fractures of the ankle and mid-foot. The instrument has a sensitivity of almost 100% and a modest specificity, and its use should reduce the number of unnecessary radiographs by 30-40%.

Ankle Injuries↗

Semi-rigid vs rigid glass fibre casting: a biomechanical assessment.

OBJECTIVES: To determine if semi-rigid synthetic casts provide any measurable advantages compared to rigid synthetic casts. BACKGROUND: Glass fibre bandages are now commonly applied immediately post-injury to provide rigid immobilisation of the limb, for both weight bearing and non-weight bearing casts. However, composite casts that have inherent flexibility are also available and it is claimed they provide some functionality. METHODS: Five members of the orthopaedic department each applied a rigid and a semi-rigid below elbow (Colles) and a below knee walking cast to a single volunteer subject. Joint immobilisation and functional movement was assessed using electrogoniometry and limb support using pressure transducers. RESULTS: Semi-rigid Colles casts provided slightly greater immobilisation at the wrist while allowing full finger function and greater support to the forearm during hand movements. Similarly, semi-rigid below knee walking casts produced greater immobilisation at the ankle while allowing more forefoot movement and were less of an impediment to walking. CONCLUSIONS: Semi-rigid casting techniques have measurable advantages compared to rigid synthetic casts and represent a further development in the conservative management of fractures and soft tissue injuries. RELEVANCE: Semi-rigid casting is a relatively new technique that can reduce some of the problems of rigid cast immobilisation and could potentially shorten the rehabilitation phase following injury. Information about the performance of these casts to assess their value in specific applications is very limited.

Ankle Injuries↗