Search PubMed⌕ Search

PubMed · 8167007

A rapid density gradient technique for separating polymorphonuclear granulocytes.

Abstract

A gradient separation technique followed by isotonic ammonium chloride haemolysis was compared with two methods for the isolation of polymorphonuclear neutrophils from blood. This technique provided a high yield, excellent purity without lymphocyte and erythrocyte contamination, and made it possible to isolate more than 50 x 10(6) human neutrophils from 15 ml of blood. The polymorphonuclear neutrophils isolated in this way were capable of generating a large amount of reactive oxygen species. This technique for the separation of polymorphonuclear neutrophils is an effective method for in vitro studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Cabanis, B Gressier, S Lebegue, C Brunet, T Dine, M Luyckx, M Cazin, J C Cazin. 1994. A rapid density gradient technique for separating polymorphonuclear granulocytes.. https://doi.org/10.1111/j.1699-0463.1994.tb04855.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Manual exfoliation of fresh tissue obviates the need for frozen sections for molecular profiling.

BACKGROUND: Simple, rapid tissue processing that preserves macromolecules will enhance translational research capabilities. Traditional fixative-based approaches for specimen preservation are ideal for histologic evaluation but are not conducive to molecular studies of nucleic acids and protein. Tissue cryosections preserve macromolecule integrity, but the process is labor intensive and technically challenging. To the authors' knowledge to date, an alternative method capable of retrieving cells while providing adequate histologic detail yet preserving macromolecule integrity has been lacking. In the current study, the authors evaluated the utility of using manual exfoliation of clinical tissue samples as a means of obtaining cells for molecular analysis. This technique possesses the advantages of fixed and frozen tissue sections without their drawbacks. This simple, rapid, nonfixative based technique is capable of preparing cells from human clinical material for further isolation without compromising the preservation of macromolecules in the tissue. METHODS: Cells from a variety of clinical resection specimens from solid tumors were directly scraped from the tissue samples using the edge of a glass microscope slide and smeared onto another slide for cytologic evaluation. The manually exfoliated cells were evaluated microscopically for cytologic quality and cellular quantity. Pure cell populations were procured by laser capture microdissection (LCM) with subsequent extraction of nucleic acids and proteins. The integrity and suitability of the recovered nucleic acids and proteins for molecular analysis were evaluated using the polymerase chain reaction (PCR), reverse transcriptase-PCR, and reverse-phase protein microarray, respectively. RESULTS: Manual exfoliation permits the selection of homogeneous cell populations by LCM based on well established cytologic characteristics. DNA and mRNA, of comparable quality to frozen sections, can be amplified from the manual exfoliation cells. Proteins of similar quality can be recovered using this technique and quantitated via reverse-phase protein microarray. CONCLUSIONS: Molecular macromolecules of high quality and sufficient quantity can be retrieved from human clinical samples using manual exfoliation and LCM to procure specific cell populations. The manual exfoliation technique does not destroy the original tissue source, thereby allowing subsequent formalin tissue fixation. The technique of manual exfoliation in conjunction with LCM can enable the molecular profiling of a sampled selected cell population. Because it does not destroy the original tissue, histologic correlation can be combined with molecular profiling.

Cell Separation↗

Dielectrophoretic segregation of different human cell types on microscope slides.

A new method for preparing cells for microscopic examination is presented in which cell mixtures are fractionated by dielectrophoretic forces and simultaneously collected into characteristic zones on slides. The method traps cells directly from the suspending medium onto the slide, reducing cell loss. Furthermore, it exploits differences in the dielectric properties of the cells, which sensitively reflect their morphology. Because different cell types are trapped in characteristic zones on the slide, the technique represents an advance over existing methods for slide preparation, such as centrifugation and smears where cells are randomly distributed. In particular, the new method should aid in the detection of rare and anomalous cell subpopulations that might otherwise go unnoticed against a high background of normal cells. As well as being suitable for traditional microscopic examination and automated slide scanning approaches, it is compatible with histochemical and immunochemical techniques, as well as emerging molecular and proteomic methods. This paper describes the rationale and design of this so-called electrosmear instrumentation and shows experimental results that verify the theory and applicability of the method with model cell lines and normal peripheral blood subpopulations.

Cell Separation↗

Development of a novel electrophoretic system for the isolation of human spermatozoa.

BACKGROUND: Optimization of assisted conception outcomes involves the development of rapid, safe, effective techniques for the isolation of functional human spermatozoa free from significant DNA damage. In this study we describe a novel electrophoretic sperm isolation technique that achieves these objectives. METHODS: The separation system consisted of a cassette comprising two 400 mul chambers separated by a polycarbonate filter containing 5 micromol/l pores and bounded by a 15 kDa polyacrylamide membrane to allow the free circulation of buffer. Semen was introduced into one chamber, current applied (75 mA at variable voltage) and within seconds a purified suspension of spermatozoa could be collected from the adjacent chamber. These cells were assessed for their count, viability, motility, morphology and DNA integrity. RESULTS: The suspensions generated by the electrophoretic separation technique contained motile, viable, morphologically normal spermatozoa and exhibited low levels of DNA damage. Moreover, these cell suspensions were free from contaminating cells, including leukocytes. The technique was comparable to discontinuous gradient centrifugation except that it took a fraction of the time and generated cells with significantly less DNA damage. CONCLUSION: Electrophoretic separation represents a highly effective, novel approach for the isolation of spermatozoa for assisted conception purposes.

Cell Separation↗