Search PubMed⌕ Search

PubMed · 8162812

[Laparoscopic or classical appendectomy? A prospective randomized study].

Abstract

Though laparoscopic appendectomy started endoscopic surgery in general surgery, it has yet not reached the acceptance as is the case with cholecystectomy. The application of this technique in possibly bland appendices and reports that the technique was accompanied by severe complications, increases the scepticism about it. This made us decide to start a randomized controlled trial: laparoscopic vs. conventional appendectomy. More than 1000 endoscopic interventions mainly performed at the gallbladder and the stomach and 165 prospectively documented and partly treated patients with acute appendicitis were the basis to start this trial. "Acute Appendicitis" was diagnosed on the basis of clinical symptoms by means of the computer-aided questionnaire of the EC-study "Acute Abdominal Pain", a self-developed validated diagnostic score, the macroscopic findings and the careful assessment of the histology of the resected appendix. Beside the technical feasibility, principle end-points were mainly intensity and course of postoperative pain measured by means of the Visual Analogue Scale (VAS) in lying, standing and moving position and the postoperative consumption of analgesics. We assessed a difference of 15 points on the VAS as clinically relevant. Of 57 patients with acute appendicitis we performed open appendectomy in 23 and laparoscopy in 34 patients according to randomization. In 9 patients of the laparoscopy group it was necessary to change over to open appendectomy for different reasons resulting in a direct comparison of 25 laparoscopies versus 23 open appendectomies. There were no differences between sociodemographic and preclinical data in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Hebebrand, H Troidl, W Spangenberger, E Neugebauer, T Schwalm, M W Günther. 1994. [Laparoscopic or classical appendectomy? A prospective randomized study].. https://pubmed.ncbi.nlm.nih.gov/8162812/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗