Search PubMed⌕ Search

PubMed · 8145084

Artifacts in computational optical-sectioning microscopy.

Abstract

We tested the most complete optical model available for computational optical-sectioning microscopy and obtained four main results. First, we observed good agreement between experimental and theoretical point-spread functions (PSF's) under a variety of imaging conditions. Second, using these PSF's, we found that a linear restoration method yielded reconstructed images of a well-defined phantom object (a 10-microns-diameter fluorescent bead) that closely resembled the theoretically determined, best-possible linear reconstruction of the object. Third, this best linear reconstruction suffered from a (to our knowledge) previously undescribed artifactual axial elongation whose principal cause was not increased axial blur but rather the conical shape of the null space intrinsic to nonconfocal three-dimensional (3D) microscopy. Fourth, when 10-microns phantom beads were embedded at different depths in a transparent medium, reconstructed bead images were progressively degraded with depth unless they were reconstructed with use of a PSF determined at the bead's depth. We conclude that (1) the optical model for optical sectioning is reasonably accurate; (2) if PSF shift variance cannot be avoided by adjustment of the optics, then reconstruction methods must be modified to account for this effect; and (3) alternative microscopical or nonlinear algorithmic approaches are required for overcoming artifacts imposed by the missing cone of frequencies that is intrinsic to nonconfocal 3D microscopy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J G McNally, C Preza, J A Conchello, L J Thomas. 1994. Artifacts in computational optical-sectioning microscopy.. https://doi.org/10.1364/josaa.11.001056

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗