Search PubMedSearch

PubMed · 8144985

Multi-applicator hyperthermia system description using scattering parameters.

Abstract

Hyperthermia systems using electromagnetic phased arrays have often been investigated from a SAR distribution point of view. One of the problems in these systems is that the achieved SAR distribution is different from the intended one because of changes in the generator signals due to mutual coupling between applications. The use of circuit theory and S-parameters in the description of an N-applicator phased array system is introduced in this paper, and a compact matrix equation giving excitation as a function of generator signals is derived. Measurement of the S-parameters is discussed using a phased array deep heating system (Danish Hyperthermia Foundation (DHF)) as an example. In a phantom experiment a significant improvement in the SAR distribution is demonstrated when the developed method is applied.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Raskmark, T Larsen, S N Hornsleth. Multi-applicator hyperthermia system description using scattering parameters.. https://doi.org/10.3109/02656739409009339

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Hygienic regulation of electromagnetic radiation of 300-3000 MHz frequency range].

The article contains analysis of national standards determining maximal allowable levels of electromagnetic exposure in some developed countries. The point of specific interest is the levels in frequency range of 300 MHz-30 GHz, as this range is widely used in most apparatus for mobile communication. Different in various countries, values of the maximal allowable levels appear to be the most strict in Russia. Incomplete knowledge of long-standing exposure to mild electromagnetic fields requires through medical and technical research to determine limits of safe application of mobile communication devices.

Electromagnetic Phenomena

[Features of control of electromagnetic radiation emitted by personal computers].

Measurements of PC electromagnetic irradiation show that the main sources are PC blocks emitting the waves of certain frequencies. Use of wide-range detectors measuring field intensity in assessment of PC electromagnetic irradiation gives unreliable results. More precise measurements by selective devices are required. Thus, it is expedient to introduce a term "spectral density of field intensity" and its maximal allowable level. In this case a frequency spectrum of PC electromagnetic irradiation is divided into 4 ranges, one of which is subjected to calculation of field intensity for each harmonic frequency, and others undergo assessment of spectral density of field intensity.

Electromagnetic Phenomena