Search PubMed⌕ Search

PubMed · 8143715

Artificial ventilation: some unresolved problems.

Abstract

In acute respiratory failure interstitial oedema, alveolar collapse, and multiple atelectasis are the main mechanisms which lead to increased venous admixture and impaired oxygenation. Thus the lung volume available for pulmonary gas exchange is considerably reduced. Since there is strong evidence that alveolar overdistension causes lung damage ('barotrauma/volutrauma') large tidal volumes and high airway pressures in mechanical ventilation have to be strictly avoided, even allowing hypoventilation ('permissive hypercapnia'). Recruitment of the collapsed alveoli by external or intrinsic PEEP, or by changing body position, is often possible. However, alveolar recruitment takes much longer than previously assumed: instead of occurring within one respiratory cycle ('inflection point'), it seems to take hours. This slow recruitment process can be effectively supported by a deliberate use of intrinsic PEEP as with inverse ratio ventilation, either in volume or pressure controlled mode. Assisted spontaneous breathing makes ventilatory support less invasive and offers considerable advantages for many patients, but there are still some restrictions. Individual adaptation may be difficult in some patients. New principles of assistance control ('proportional assist ventilation') may improve individual adaptation. New concepts for weaning in COPD patients seem to offer better clinical strategies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Burchardi, M Sydow. 1994. Artificial ventilation: some unresolved problems.. https://searchpubmed.org/record/pubmed%3A8143715/artificial-ventilation-some-unresolved-problems

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗