First-pass ventricular ejection fraction using a single-crystal nuclear camera.

Abstract

UNLABELLED: The purpose of the study was to evaluate the reliability of ejection fractions obtained from first-pass radionuclide ventriculography with a large field-of-view tomographic single-crystal gamma camera. METHODS: A SPECT camera had its electronics redesigned to improve counting efficiency and was equipped with an experimental ultra-high sensitivity collimator. Left ventricular ejection fraction (LVEF) was measured in 28 patients by 30 degrees RAO first-pass imaging and by "best septal view" LAO planar equilibrium radionuclide ventriculography on a conventional small field of view Anger camera. For 28 other patients, first-pass ejection fractions were compared to multicrystal gamma camera values. Visual analysis was performed to judge clinical acceptability of first-pass images for identification of wall-motion abnormalities. RESULTS: Linear regression analysis of first-pass against equilibrium ejection fraction demonstrated good correlation (r = 0.92; slope = 0.90; intercept = 3.8; s.e.e. = 6.4%). First-pass ejection fraction values also correlated linearly with multicrystal camera values for the left ventricle (r = 0.94; slope = 1.05; intercept = 1.3; s.e.e. = 5.3%). For a subgroup of 19 patients, single-crystal camera right ventricle ejection fraction demonstrated good correlation with multicrystal camera values (r = 0.82; slope = 1.15; intercept = 1.3; s.e.e. = 6.1%). Interobserver variability correlated as r = 0.99 for LVEF ejection fraction and r = 0.92 for RVEF. Chi-square analysis of single-crystal first-pass image visual scores versus those from the gated equilibrium acquisitions showed close agreement (p < 10(-8)). CONCLUSIONS: The evaluated camera/collimator system measured left and right ventricular ejection fraction accurately. Lung frame correction and dual regions were superior to paraventricular background correction and a fixed end-diastolic region.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Nichols, E G DePuey, N Gooneratne, H Salensky, M Friedman, S Cochoff. 1994. First-pass ventricular ejection fraction using a single-crystal nuclear camera.. https://pubmed.ncbi.nlm.nih.gov/8046481/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A feasibility study on the use of visible and short wavelengths in the near-infrared region for the non-destructive measurement of wine composition.

The aim of this study was to explore the capability of spectroscopy in the visible (Vis) and short wavelength near-infrared (NIR) regions for the non-destructive measurement of wine composition in intact bottles. In this study we analysed a wide range of commercial wines obtained in Australia in different types of bottles (e.g. colours, diameters and heights), including different wine styles and varieties. Wine bottles were scanned in the Vis-NIR region (600-1,100 nm) in a monochromator instrument in transflectance mode. Principal component analysis (PCA) and partial least-squares (PLS) regression were used to interpret the spectra and develop calibrations for wine composition. Due to the relatively small number of samples available full cross-validation (leave-one-out) was used as validation. The coefficient of correlation in calibration [Formula: see text] and the standard error of cross-validation (SECV) were 0.67 (SECV: 0.48%), 0.83 (SECV: 4.01 mg L-1), 0.70 (SECV: 28.6 mg L-1) and 0.50 (SECV: 0.15) for alcohol content, total SO2, free SO2 and pH, respectively, in the set of wine samples analysed. These preliminary results showed that the assessment of wine composition by Vis and short wavelengths in the NIR is possible for either qualitative analysis (e.g. low-, medium- and high-quality grading), or for screening of composition during bottling and storage. Although low accuracy and precision were obtained for the chemical parameters routinely analysed in wine, calibration models for the chemical parameters were considered acceptable for screening purposes in terms of the standard errors obtained.

Feasibility Studies↗

Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer.

PURPOSE: In external beam radiotherapy (EBRT) and especially in intensity-modulated radiotherapy (IMRT), the accuracy of the dose distribution in the patient is of utmost importance. It was investigated whether image guided in vivo dosimetry in the rectum is a reliable method for online dose verification. METHODS AND MATERIALS: Twenty-one dose measurements were performed with an ionization chamber in the rectum of 7 patients undergoing IMRT for prostate cancer. The position of the probe was determined with cone beam computed tomography (CBCT). The point of measurement was determined relative to the isocenter and relative to an anatomic reference point. The dose deviations relative to the corresponding doses in the treatment plan were calculated. With an offline CT soft-tissue match, patient positioning after ultrasound was verified. RESULTS: The mean magnitude +/- standard deviation (SD) of patient positioning errors was 3.0 +/- 2.5 mm, 5.1 +/- 4.9 mm, and 4.3 +/- 2.4 mm in the left-right, anteroposterior and craniocaudal direction. The dose deviations in points at corresponding positions relative to the isocenter were -1.4 +/- 4.9% (mean +/- SD). The mean dose deviation at corresponding anatomic positions was 6.5 +/- 21.6%. In the rare event of insufficient patient positioning, dose deviations could be >30% because of the close proximity of the probe and the posterior dose gradient. CONCLUSIONS: Image-guided dosimetry in the rectum during IMRT of the prostate is a feasible and reliable direct method for dose verification when probe position is effectively controlled.

Feasibility Studies↗