PubMed · 8026849
Single site electromyograph amplitude estimation.
Abstract
Previous investigators have experimentally demonstrated and/or analytically predicted that temporal whitening of the surface electromyograph (EMG) waveform prior to demodulation improves the EMG amplitude estimate [1]-[6]. However, no systematic study of the influence of various whitening filters upon amplitude estimate performance has been reported. This paper describes a phenomenological mathematical model of a single site of the surface EMG waveform and reports on experimental studies which examined the performance of several temporal whitening filters. Surface EMG waveforms were sampled during nonfatiguing, constant-force, isometric contractions of the biceps or triceps muscles, over the range of 10-75% maximum voluntary contraction. A signal-to-noise ratio (SNR) was computed from each amplitude estimate (deviations about the mean value of the estimate were considered as noise). A moving average root mean square estimator (245ms window) provided an average +/- standard deviation (A +/- SD) SNR of 10.7 +/- 3.3 for the individual recordings. Temporal whitening with one fourth-order whitening filter designed per site improved the A +/- SD SNR to 17.6 +/- 6.0.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
E A Clancy, N Hogan. 1994. Single site electromyograph amplitude estimation.. https://doi.org/10.1109/10.284927. https://searchpubmed.org/record/pubmed%3A8026849/single-site-electromyograph-amplitude-estimation