Search PubMed⌕ Search

PubMed · 80221

Mahaim conduction producing left axis deviation and normal QRS.

Abstract

An unusual patient is described in whom electrophysiological studies strongly suggest the occurrence of Mahaim conduction. The patient whose electrocardiogram previously showed a left anterior hemiblock pattern then developed advanced atrioventricular (AV) block (AH block). Beats conducted through the atrioventricular node always had a short HV interval (20 ms) and QRS complexes of left anterior hemiblock pattern. Junctional escape beats always had a normal HV interval (50 ms) with normal intraventricular conduction. His bundle pacing showed the StV interval and QRS contour of escape beats. These findings suggest the existence of an accessory pathway (Mahaim fibres) passing from the area of block, presumably the uppermost portion of the His bundle, to the posteroinferior division of the left bundle-branch. The surface electrocardiogram did not show the characteristic delta wave of the Wolff-Parkinson-White syndrome. Our observations suggest that patients in whom there is conduction along Mahaim fibres may show only the pattern of intraventricular conduction defect without a delta wave.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Matsuguchi, A Takeshita, N Makino, S Tanaka, O Nakagaki, A Kuroiwa, M Nakamura. 1978. Mahaim conduction producing left axis deviation and normal QRS.. https://doi.org/10.1136/hrt.40.8.902

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[CME-ECG 2].

Explore the source record for details and available documents.

Cardiac Complexes, Premature↗

Extrasystoles: side effect of kangaroo care?

OBJECTIVE: To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. DESIGN: Case report. PATIENT: Preterm infant. MEASUREMENTS AND MAIN RESULTS: A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. CONCLUSIONS: ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

Cardiac Complexes, Premature↗