[Ventilation method plan in daily operations--a practical study].

Abstract

On three days each we measured particles and airborne bacteria in ten ventilated operating theatres. Modern air conditioning systems achieved a significant reduction of air-pollution. Vertical systems proved to be more effective than horizontal systems. Workday conditions made several problems: During high personal activity a body exhaust system was not able to reduce the concentration of airborne bacteria; doors near the operating table and objects in the airstream had a negative effect; there was more personal than necessary in the operating theatres; some activities took place without a specific purpose and resulted in raised particle and bacteria contamination; early clearing of materials, before the operation ended, increased turbulences and door movements. A short break in personal activity before the first skin cut is recommended to reduce high air contamination due to the preparation of the operating room and the patient. One of the ventilation systems was insufficiently operated by personal. We recommend continuous measurement of particles near the operating field in order to control the input of airborne particles and bacteria into the wound.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W E Bischoff, U Sander, J Sander. 1994. [Ventilation method plan in daily operations--a practical study].. https://searchpubmed.org/record/pubmed%3A8011060/ventilation-method-plan-in-daily-operations-a-practical-study

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Monitoring of biofilm-associated Legionella pneumophila on different substrata in model cooling tower system.

Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.

Air Conditioning↗

Real-time evaluation of ventilation filter-bank systems.

This study evaluated two government facility ventilation systems. One was a metropolitan government office complex with a recirculation system where outside air was the makeup air; the other was a NIOSH facility that used 100% outside air with no recirculation. The methodology employed was a modified American Society of Agricultural Engineers standard (S525) for testing total enclosure filtration efficiency, in agricultural tractor cabs, with optical particle counters (OPC). The low-efficiency bag filters were tested when new and after being in the ventilation system for 3 months. The replacement medium-efficiency filters were evaluated for 6 months (the manufacturer's suggested change-out schedule). These eight-chamber, medium-efficiency filters had an increased filter surface area that resulted in increased airflow through the system. Unfortunately, these filters contained electrostatic filter media and lost filtration efficiency rapidly, which was subsequently confirmed in a 30-day study conducted to determine an appropriate change-out schedule for the eight-chamber bag filters. The study determined that less than 6 months' use was justified due to the reduced efficiency of the electrostatic filter media. The NIOSH facility's air handler #8 (100% outside air unit) was upgraded from electrostatic bag filters, which had a suggested 9-month change-out schedule, to V Bank mechanical, wet-laid, glass fiber filters. The results of a 3-year evaluation showed that the V Bank filters had better filter efficiency after 3 years of service than the electrostatic filters had at 9 months. Both studies employed matched OPC instruments to reduce instrument-to-instrument bias. The methodology is adaptable to monitoring the total efficiency of most air filtration systems, and results can help make decisions about upgrading filter performance.

Air Conditioning↗

Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems.

We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.

Air Conditioning↗