Search PubMed⌕ Search

PubMed · 8002832

Time parameters for glaucoma procedures.

Abstract

Changes in physician reimbursement and the practice environment have emphasized the importance of determining physician time for procedures and services. Forty-five percent of the members of the American Glaucoma Society responded to a mail survey of estimates of the length of time and number of visits for the preoperative, operative, and 90-day postoperative care for six common glaucoma procedures. Results suggest a significant underestimation of time for trabeculectomies exists in the original and new resource-based relative value scale work values. Further, 47% to 53% of surgeons hospitalize patients on at least the first postoperative day. There were no apparent time efficiencies between "high-" and "low-volume" respondents. Thus, careful attention should be paid to the accuracy of certain time estimates and the resulting work values in the resource-based relative value scale. Additional work in this and other areas may prove illuminating.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P P Lee, S Rao, S Azen, K L Linton, D S Minckler. 1994. Time parameters for glaucoma procedures.. https://doi.org/10.1001/archopht.1994.01090180053034

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗