Search PubMedSearch

PubMed · 7975321

Spatial integration in position acuity.

Abstract

To determine whether and how spatial integration takes place in position acuity, bisection and Vernier thresholds were measured in the fovea of four normal observers with spatially "undersampled" dark lines (i.e. lines comprised of discrete samples). The size, contrast, and density of samples, and the separation of the lines were varied. For a given sampling density, sample size (0.17-2.72 min) has negligible effect on position threshold. For all sample sizes, position threshold decreases as sampling density increases, indicating that spatial integration takes place. The form of spatial integration depends on line separation. At the optimal line separation (2 min for bisection and 0 min for Vernier), position threshold decreases as sampling density increases with a slope of about -0.8 on log axes, steeper than a slope of -0.5 as would be expected from statistical position averaging. This effect of sampling density can be completely explained by spatial contrast summation for visibility. At the 16 min line separation, position threshold also decreases as sampling density increases but with a slope shallower than -0.5. However, this effect of sampling density can not be explained by contrast summation. Position thresholds decrease even after discounting the effect of contrast summation on visibility, suggesting a genuine position averaging. These findings are independent of line orientation (horizontal or vertical), and hold for both random and uniform dot distributions, and for both bisection and Vernier. Thus, two separate mechanisms of position acuity are suggested. A spatial filter mechanism operates at the optimal (or narrow) line separation where position threshold is critically dependent on stimulus visibility. A local sign mechanism operates at the relatively wider line separation where position acuity benefits from local sign position averaging. For both mechanisms, spatial integration is not perfect.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Wang, D M Levi. 1994. Spatial integration in position acuity.. https://doi.org/10.1016/0042-6989(94)90055-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spatial and temporal coherence in perceptual binding.

Component visual features of objects are registered by distributed patterns of activity among neurons comprising multiple pathways and visual areas. How these distributed patterns of activity give rise to unified representations of objects remains unresolved, although one recent, controversial view posits temporal coherence of neural activity as a binding agent. Motivated by the possible role of temporal coherence in feature binding, we devised a novel psychophysical task that requires the detection of temporal coherence among features comprising complex visual images. Results show that human observers can more easily detect synchronized patterns of temporal contrast modulation within hybrid visual images composed of two components when those components are drawn from the same original picture. Evidently, time-varying changes within spatially coherent features produce more salient neural signals.

Contrast Sensitivity

Pitfalls in estimating motion detector receptive field geometry.

A number of psychophysical investigations have used spatial-summation methods to estimate the receptive field (RF) geometry of motion detectors by exploring how psychophysical thresholds change with stimulus height and/or width. This approach is based on the idea that an observer's ability to detect motion direction is strongly determined by the relationship between the stimulus geometry (height and width) and the RF of the activated motion detectors. Our results show that previous estimates of RF geometry can depend significantly on stimulus position in the visual field as well as on the stimulus height-to-width ratio. The data further show that RF estimates depend on the stimulus in a manner that is inconsistent with basic predictions derived from current motion detector models. Hence previous estimates of height, width, and height-to-width ratios of motion detector RFs are inaccurate and unreliable. This inaccuracy/unreliability is attributed to a number of sources. These include incorrect fixed-parameter values in model fits, as well as the confounding of physiological spatial summation area through combined use of contrast thresholds and Gaussian-windowed stimuli. A third source of error is an asymmetric variation of spatiotemporal correlation in the stimulus as either its height or width is varied (and the other dimension held constant). Most importantly, a fourth source of unreliability is attributed to the existence of a nonlinear, nonmonotonic distribution of motion detectors in the visual field that has been previously described and is a natural result of visual anatomy.

Contrast Sensitivity