Fluorescence array detector for large-field quantitative fluorescence cytometry.

Abstract

A prototypic fluorescence array detector (FAD) has been designed and constructed which is capable of quantifying single-cell fluorescence emissions from a statistically significant population of cell-sized objects (over 10(3)) on a solid substrate. The system is comprised of a cryogenically cooled CCD, 50 mW air-cooled argon ion laser, and optics that image a large (1 x 1 cm) field at 1:1 (no magnification). The CCD is effectively treated as a two-dimensional array of 2.7 x 10(5) independent 20 x 20 microns photodetectors, with each cell-sized object imaged across only a few CCD pixels. Algorithms have been developed for focusing, image segmentation, shading correction, and noise rejection; performance data for the FAD with fluorescent calibration beads are presented. The FAD is a simple alternative to microscope-based imaging cytometry, allowing large-field imaging without a scanning stage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K D Wittrup, R J Westerman, R Desai. 1994-07-01. Fluorescence array detector for large-field quantitative fluorescence cytometry.. https://doi.org/10.1002/cyto.990160304

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Twenty years of external quality assurance in clinical cell analysis--a tribute to Jean-Luc D'Hautcourt.

External quality assurance (EQA) programs in clinical cell analysis are now a consolidated item of laboratory practice. All the flow cytometric testings with an impact on clinical decision making have been submitted to regular EQA programs during the last 20 years, and this has produced internationally homogeneous guidelines, with a remarkable improvement in result reproducibility.Jean-Luc D'Hautcourt was a pioneer in this field, and his valuable contributions to flow cytometric method standardization and to the dissemination of the educational aspects of EQA programs are recognized. The different methodological approaches undertaken in the United States and Europe are discussed. The educational role of SIHON in the Benelux Countries and of UKNEQAS for Leucocyte Immunophenotyping worldwide is emphasized. Accredited and accreditating EQA programs require an impressive degree of organization and technical knowledge, so that only major international providers can afford such a task nowadays. However, small local studies still provide the necessary stimulus to the continuous improvement of the scientifical aspects of EQA schemes.

Flow Cytometry↗

Distribution of flower morphs, ploidy level and sexual reproduction of the invasive weed Oxalis pes-caprae in the western area of the Mediterranean region.

BACKGROUND AND AIMS: Oxalis pes-caprae is a widespread invasive weed in regions with a Mediterranean climate. In its native habitat (southern Africa) this species has been reported as heterostylous with trimorphic flowers and a self- and morph-incompatible reproductive system. In most of the areas invaded, only a pentaploid short-styled morphotype that reproduces mainly asexually by bulbils is reported, but this has only been confirmed empirically. This study aims to analyse the floral morph proportions in a wide distribution area, test the sexual female success, and explain the causes of low sexual reproduction of this species in the western area of the Mediterranean Basin. METHODS: Fifty-five populations of O. pes-caprae were sampled in the Iberian Peninsula and Morocco to evaluate the floral morph ratio and individual fruit set. In plants from a dimorphic population, hand-pollination experiments were performed to evaluate the effect of the pollen source on pollen tube growth through the style. The ploidy level and genome size of individuals of each floral morph were analysed using flow cytometry. KEY RESULTS: From the populations studied 89.1 % were monomorphic, with most of them containing the short-styled (SS) floral morph, and 10.9 % were dimorphic containing long-styled (LS) and SS morphs. In some of these, isoplethy was verified but no fruit production was observed in any population. A sterile form was also recorded in several populations. Hand-pollination experiments revealed that pollen grains germinated over recipient stigmas. In intermorph crossings, pollen tubes were able to develop and fruit initiation was observed in some cases, while in intramorph pollinations, pollen tube development was sporadic and no fruit initiation was observed. All individuals within each floral form presented the same DNA ploidy level: SS plants were pentaploid and LS and the sterile form were tetraploid. CONCLUSIONS: The low or null sexual reproduction success of this species in the area of invasion studied seems related with the high frequency of monomorphic populations, the unequal proportion of floral morphs in dimorphic populations and the presence of different ploidy levels between SS and LS morphs. The discovery of the occurrence of an LS floral morph and a sterile form, whose invading capacity in these areas is as yet unknown, will be valuable information for management programmes.

Flow Cytometry↗

The impact of interleukin-6 promoter -597/-572/-174genotype on interleukin-6 production after lipopolysaccharide stimulation.

Interleukin (IL)-6 is a pleiotropic cytokine, produced by different cells. There is accumulating evidence that IL-6 promoter polymorphisms impact substantially on various diseases and we identified kidney transplant recipients carrying the IL-6 GGG/GGG (-597/-572/-174)genotype to have superior graft survival. To prove a functional impact on gene expression, we analysed systematically IL-6 production in healthy individuals with respect to the IL-6 (-597/-572/-174)genotype. IL-6 was determined in 100 healthy blood donors at protein and mRNA levels upon specific stimulation in monocytes and T lymphocytes under whole blood conditions. GGG/GGG individuals showed a lower IL-6 secretion upon lipopolysaccharide (LPS)-stimulation versus all others (P = 0.039). This link was even stronger when (-597) and (-174)GG genotypes were reanalysed separately (P = 0.008, P = 0.017). However, we found neither a difference at the mRNA level or percentage of CD14(+) cells nor after T cell stimulation. We found evidence for the IL-6 (-597/-572/-174)genotype to affect IL-6 synthesis, i.e. lower levels of IL-6 protein upon LPS-stimulation in GGG/GGG individuals. Further studies are needed in kidney transplant recipients to investigate the potential link between the GGG/GGG genotype and graft survival. In line with this, determination of the genetic risk profiles might be promising to improve the transplant outcome in the individual patient.

Flow Cytometry↗