Interactive intraoperative localization using an infrared-based system.

Abstract

We discuss new methods of localizing and treating brain lesions for both the conventional method of a base-ring fixed to the patient's skull (referred to as frame-based procedures) and the new method of frameless procedures (no base ring). Frame-based procedures are used for finding a precise instrument position during neurosurgical procedures, such as stereotactic biopsy of deep-seated lesions, placing electrodes for functional stereotaxis or catheters with radioactive seeds for brachytherapy, or even the placement of a stereotactic retractor or endoscope for removal or internal decompression of lesions. In such procedures, the intraoperative image localization of instruments becomes useful as it tracks instruments as they travel through the preplanned trajectory. Additional intraoperative digitization of surgical instruments, e.g., bipolar suction, biopsy forceps, microscope, ultrasound probe, etc, can be achieved during the stereotactic resection of eloquent areas or deep intracranial lesions by adding an infrared-based system. Frameless procedures broaden the range of surgical approaches, image guidance planning, and operative procedures, since no ring is attached to the patient's head which might interfere with the surgical approach, and offers logistic advantages in scheduling diagnostic studies. Frameless diagnostic studies employ anatomical markers and/or surface matching techniques for data registration in the computer software surgical preplanning program. This simplifies scheduling of the procedures since the image study does not need to be acquired the same day as surgery. Frameless diagnostic studies allow for the use of more than one type of imaging data for planning and optimization of surgical procedures, and greatly improve patient tolerance and comfort during these procedures and during surgery, as compared with frame-based procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L J Zamorano, L Nolte, A M Kadi, Z Jiang. 1993. Interactive intraoperative localization using an infrared-based system.. https://doi.org/10.1080/01616412.1993.11740150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of filler fraction and filler surface treatment on wear of microfilled composites.

OBJECTIVES: The aim of this study was to determine the effect of filler content and surface treatment on the wear of microfilled composites. METHODS: Four microfilled composites with different filler contents (A=20, B=25, C=30, and D=35 vol.%) were made with a light-cured resin (Bis-GMA/UDMA/TEGDMA). The surface treatment of the colloidal silica in each varied: F=functional silane, NF=non-functional silane, U=untreated. Silux Plus served as a control. Specimens were made in steel molds and cured in a light curing unit Triad II (40s/side). Abrasion and attrition wear were evaluated in vitro in a wear tester (OHSU oral wear simulator) with an abrasive slurry (poppy seeds + PMMA) and a human enamel antagonist. The average of five specimens was computed and compared using a ANOVA/Tukey's test at P < or = 0.05. The surface of the wear patterns and the distribution of filler particles were examined using a scanning electron microscope and digital imaging. RESULTS: As filler volume increased, wear was reduced regardless of filler treatment. Amounts of wear for specimens C and D were significantly lower than specimens A and B. Composites with functional silane treated microfiller (Group F) produced significantly less wear than those with non-functional microfiller (Group NF) at 30 and 35 vol.%, and less than the untreated microfiller (Group U) at 30 vol.%. Scanning electron microscopy of specimens of group NF showed large filler agglomerates (size > 1 microm) in the resin matrix, while specimens of group F and U showed fewer agglomerates. Digital imaging analysis revealed small filler clusters (size < or = 1 microm) in the resin matrix of all specimens. SIGNIFICANCE: Wear resistance of microfilled composites is enhanced by higher filler volumes irrespective of surface treatment, but good filler/matrix adhesion is needed to minimize wear.

Analog-Digital Conversion↗

Relative value of analog and digital teaching files.

RATIONALE AND OBJECTIVES: This study was performed to determine if it is financially reasonable for radiology residency programs that create and maintain their own teaching files to switch from analog teaching files (ATFs) to digital teaching files (DTFs). MATERIALS AND METHODS: Radiology residency program directors were surveyed electronically about the monetary value and importance of conventional ATFs and DTFs. The costs for maintaining each type of file were calculated at the authors' institution. RESULTS: Surveys were sent to the program directors of all 197 accredited radiology residencies. Responses were received from 48 (24%). DTFs were scored as more important than ATFs, but the difference was not significant (P = .22). DTFs were rated as less complete (P = .01) but more current (P << .001) than ATFs. DTFs included the American College of Radiology Learning File (85%), in-house productions (77%), and other commercially available products (63%). Thirty percent of respondents had a DTF integrated into a picture archiving and communication system, and 28% reported having a technician dedicated to the teaching file. Program directors ascribed total median dollar values of $250 and $3,000 per year to their ATFs and DTFs, respectively. The annual costs at the authors' institution were much higher than these ascribed values: $44,720 ($91 per case) for maintaining a DTF produced in house and $24,601 ($50 per case) for maintaining an ATF, excluding physician time. CONCLUSION: Program directors are more willing to pay for a DTF than an ATF. For both, the costs of maintenance are great and the relative monetary value is low.

Analog-Digital Conversion↗

Circulating nitrite anions are a directly acting vasodilator and are donors for nitric oxide.

Inhaled nitric oxide (NO) is a pulmonary vasodilator, but also acts systemically, causing negative cardiac inotropic effects and a fall in systemic vascular resistance. Circulating metabolites of NO are presumed to be responsible. We questioned the role of nitrite anions and the manner in which they might contribute to these effects. Nitrite and nitrate anions coexist in blood, while circulating levels of dissolved NO are very low. Nitrate anions are not biologically active, but nitrite anions may have a biological role through the release of NO. In vitro, at 37 degrees C and in aerated Krebs bicarbonate solution, the steady-state concentration of dissolved NO was proportional to the concentration of NO in the gas. Nanomolar concentrations of dissolved NO coexisted with micromolar concentrations of nitrite anions. The idea of an equilibrium between the two in solution was also supported by the observed release of NO from nitrite anions in the absence of gas. With rings of precontracted pig pulmonary arteries (prostaglandin F(2alpha); 10 micromol/l), the steady-state concentration of dissolved NO causing 50% relaxation (EC(50)) was 0.84+/-0.25 nmol/l, corresponding to a gaseous concentration of 2.2 p.p.m. The EC(50) of nitrite was 4.5+/-0.7 micromol/l, a concentration normally found in plasma. The estimated concentration of dissolved NO derived from this nitrite was 4.5 pmol/l, some 100 times lower than would be needed to cause relaxation. The rate of exhalation of NO was increased and pulmonary vascular resistance was reduced by the addition of nitrite solution to the perfusate of isolated perfused and ventilated pig lungs, but only when millimolar concentrations were achieved. Thus circulating nitrite anions are a direct vasodilator, only being a carrier of effective amounts of "free" NO at higher than physiological concentrations.

Analog-Digital Conversion↗