Search PubMed⌕ Search

PubMed · 7873186

A program for analyzing enzyme rate data obtained from a microplate reader.

Abstract

A computer program (microplate analysis [MPA] program) is described that allows manipulation of kinetic data obtained from a microplate reader. It is particularly useful for obtaining enzyme velocities from microplate data. Data can be displayed either as an 8 x 12 grid which shows all microplate wells at low resolution or as single enzyme progress curves which show the reaction time course in greater detail and allow data manipulation (single curve mode). In the single curve mode, the X-axis of the progress curves can be displayed either as discrete time points numbered from the first to the last or as real time in seconds. The program can calculate the maximum, minimum or initial reaction rate by either linear or robust regression. In the single curve mode, the user can control the range of data points included in the regression analysis and the number of data points over which the rate is averaged. In this way, the maximum (or minimum) rate within a specific range of data can be determined. The major advantage of the MPA program is that the range settings are specific to each well. This gives the user complete control over the presentation and calculation of the kinetic data. The MPA program requires an AS-CII file containing data blocks of 96 sequential absorbance readings for each time point and the time interval between successive absorbance readings.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S P Brooks. 1994. A program for analyzing enzyme rate data obtained from a microplate reader.. https://pubmed.ncbi.nlm.nih.gov/7873186/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification of cholesterol in foods using non-aqueous capillary electrophoresis.

A simple method for the rapid quantification of cholesterol in egg yolk and milk by non-aqueous capillary electrophoresis (NACE) is described in this paper. The samples were treated with saponification and then quantified by NACE, in which 100 mM sodium acetate-acetic acid in methanol was employed as the running buffer. The correlation coefficient between the cholesterol concentration and the corresponding peak area was 0.999. The detection limit of cholesterol was 5 microg/ml (twice the signal-to-noise ratio). This method can be used as a routine method for the rapid and sensitive determination of cholesterol in foods.

Calibration↗

Simultaneous assay of sildenafil and desmethylsildenafil in human plasma using liquid chromatography-tandem mass spectrometry on silica column with aqueous-organic mobile phase.

A liquid chromatography-tandem mass spectrometry method was developed for the analysis of sildenafil (SIL) and its metabolite desmethylsildenafil (DMS) in human plasma. Samples were accurately transferred to 96-well plates using a liquid handler (Multiprobe II). Solid-phase extraction was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C8 and cation-exchange mixed-mode sorbent. The extract was injected onto a silica column with an aqueous-organic mobile phase, a combination that was novel for improving the method sensitivity. The low limit of quantitation was 1.0 ng/ml for both SIL and DMS. The method was validated to meet the criteria of current industrial guidance for quantitative bioanalytical methods.

Calibration↗

Quantification of methyldopa in human plasma by high-performance liquid chromatography-electrospray tandem mass spectrometry application to a bioequivalence study.

A method based on LC-MS-MS is described for the determination of methyldopa in human plasma using dopa-phenyl-D3 as the internal standard. The method has a chromatographic run time of 5.5 min and was linear in the range of 20-5000 ng/ml. The limit of quantitation was 20 ng/ml, the intra-day precisions were 7.3, 5.4 and 4.3% and the intra-day accuracies were -8.0, -1.3 and -2.0% for 30, 600 and 3000 ng/ml, respectively. The inter-day precisions were 7.7, 0.5 and 0.7% and the inter-day accuracies were 0.2, -1.1 and -2.3%, respectively, for the above concentrations. This method was employed in a bioequivalence study of two tablet formulations of methyldopa.

Calibration↗