CT scans through metal scanning technique versus hardware composition.

Abstract

OBJECTIVE: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. METHODS: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360 degrees rotation, 140 kVp, 140 mA, 3 s, 360 degrees rotation, 140 kVp, 140 mA, 4 s, 420 degrees rotation. RESULTS: Titanium was superior to cobalt-chrome (p < .0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420 degrees compared to the standard 360 degrees. CONCLUSION: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420 degrees scan arc to improve the image quality of bone surrounded by metal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Haramati, R B Staron, K Mazel-Sperling, K Freeman, E L Nickoloff, C Barax, F Feldman. CT scans through metal scanning technique versus hardware composition.. https://doi.org/10.1016/0895-6111(94)90080-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sex and age diagnosis by ischium morphometric analysis.

The growth of four variables of the ischium was analysed by polynomial regression in order to evaluate its significance and its capacity for age and sex determination during and after growth. The material used was 327 specimens ranging from birth to 97 years of age from four documented west European collections. The growth curves were calculated for ischium length and three new variables of the acetabular surface (horizontal diameter of ischium acetabular surface, vertical diameter of ischium acetabular surface and ischium acetabular index). All curves, except those of the female series of vertical diameter of ischium acetabular surface and its index, showed a lineal growth corresponding to vertical variables. All variables studied, except the ischium acetabular index, can be used variables for adult sexual discrimination. Furthermore, ischium length and the horizontal and vertical diameters of the acetabular surface can be useful for sub-adult age determination in archaeological samples, as well as in forensic samples. However, the ischium length is the best variable, as it can be applied to all the growth ages.

Acetabulum↗

The acetabular blood supply: implications for periacetabular osteotomies.

As the popularity of juxta-acetabular osteotomies in adults increases, concern arises that such a procedure will potentially cause avascular necrosis of the acetabular fragment. In order to verify the remaining vascularization after a Bernese periacetabular osteotomy, an injection study with colored latex was performed. The vascularity of the outside of the periacetabular bone was studied in 16 hips after injection of colored latex into the abdominal aorta and the inside in four hips. To confirm the conclusions drawn from the anatomic study, a Bernese periacetabular osteotomy was performed in two additional hips after latex injection. This study demonstrated that through a modified Smith-Peterson approach and with execution of the osteotomies from the inside of the pelvis the acetabular fragment remains vascularized by the supra-acetabular and acetabular branches of the superior gluteal artery, the obturator artery and the inferior gluteal artery. Some uncertainty remains about how much correction is tolerated by the smaller blood vessels.

Acetabulum↗