Search PubMed⌕ Search

PubMed · 7770549

Gravity effect on lymphocyte deformation through cell shape change.

Abstract

The effects on human cells (lymphocyte) immersed in a culture liquid under microgravity environment has been investigated. The study was based on the numerical simulation of the Morphology of human cells affected by the time dependent variation of gravity acceleration ranging from 10(-3) to 2 g(o) (g(o) = 9.81 m/s2) in 15 s. Both the free floating cells and the cells which came into contact with the upper and lower inclined walls imposed by the time-dependent reduced gravity acceleration were considered in this study. The results show that, when the gravity acceleration increased, the cell morphology changed from spherical to horizontally elongated ellipsoid for both the free floating cells and the stationary cells on the lower inclined wall while the cell morphology varied from spherical to vertically-elongated ellipsoid for the cells hanging on the upper inclined wall. A test of the deformation of human cells exposed to the variation of gravity levels, carried out in the KC-135 free fall aircraft, show that the results of experimental observations agree exactly with the theoretical model computation described in this paper. These results will be useful for study of the behavior and morphology of cells in space.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Hung, Y D Tsao, G F Spauling. 1995. Gravity effect on lymphocyte deformation through cell shape change.. https://pubmed.ncbi.nlm.nih.gov/7770549/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

pH and cell volume effects on H2O and phosphoryl resonance splitting in rapid-spinning NMR of red cells.

Two resonances are seen in the (1)H-NMR spectrum of water in erythrocyte suspensions spun at the magic angle, a broad signal from water inside the cells and a sharp signal from extracellular water. The splitting is a result of a true chemical shift difference between the two populations, as bulk magnetic susceptibility effects are negated at the magic angle. The pH dependence of this chemical shift difference in erythrocyte suspensions was investigated. Splittings of 16.7 +/- 0.1, 18.9 +/- 0.9, and 21.0 +/- 0.2 Hz were observed at pH 6.0, 7.0, and 8.5, respectively; however, this was accompanied by a change in the mean cell volume. To account for any contribution from the volume change, the osmolality of the pH 6.0 and 8.5 suspensions was adjusted to equalize the cell volume between samples at the three pHs. Under these conditions, the splitting was 18.3 +/- 0.1 and 18.6 +/- 0.1 Hz at pH 6.0 and 8.5, respectively. Thus the observed chemical shift difference between the two water resonances was independent of pH. Therefore the splitting of the water resonance was concluded to be directly proportional to the protein concentration within the cell. Measurements of the magnetic susceptibility difference between the two compartments were also carried out, yielding a value of 2.0 +/- 0.2 x 10(-7) (SI units) for erythrocytes in isotonic saline at pH 7.0.

Cell Size↗

Correlation between erythrocytes deformability and size: a study using a microchannel based cell analyzer.

The deformability of erythrocytes is of great importance for oxygen delivery in the microcirculation [Lipowsky, H.H., 2005. Microvascular rheology and hemodynamics. Microcirculation 12, 5-15]. Aging of erythrocytes is associated with a reduction in deformability and also in size. The present work describes an automated cell analyzer which utilizes a glass microchannel and advanced image processing software. Erythrocytes suspended in a high viscosity medium are filmed flowing through the microchannel. Under these conditions, the cells assume different orientations and undergo varying deformations according to their location in the velocity profile. The cell analyzer enables the measurement of individual erythrocyte velocity, deformability and volume at varying depths within the microchannel. The volume of the cells is calculated based on the experimental data and a fluid mechanics model. The results obtained show that, on average, the deformability of the cells increases with increase in their size. Additionally, the behavior of RBCs in a microchannel is investigated, showing promising diagnostic possibilities.

Cell Size↗

Microtubule organization in three-dimensional confined geometries: evaluating the role of elasticity through a combined in vitro and modeling approach.

Microtubules or microtubule bundles in cells often grow longer than the size of the cell, which causes their shape and organization to adapt to constraints imposed by the cell geometry. We test the reciprocal role of elasticity and confinement in the organization of growing microtubules in a confining box-like geometry, in the absence of other (active) microtubule organizing processes. This is inspired, for example, by the cortical microtubule array of elongating plant cells, where microtubules are typically organized in an aligned array transverse to the cell elongation axis. The method we adopt is a combination of analytical calculations, in which the polymers are modeled as inextensible filaments with bending elasticity confined to a two-dimensional surface that defines the limits of a three-dimensional space, and in vitro experiments, in which microtubules are polymerized from nucleation seeds in microfabricated chambers. We show that these features are sufficient to organize the polymers in aligned, coiling configurations as for example observed in plant cells. Though elasticity can account for the regularity of these arrays, it cannot account for a transverse orientation of microtubules to the cell's long axis. We therefore conclude that an additional active, force-generating process is necessary to create a coiling configuration perpendicular to the long axis of the cell.

Cell Size↗