Search PubMedSearch

PubMed · 7766768

Comparing non-nested regression models.

Abstract

A method for comparing the fits of two non-nested models, based on a suggestion of Davidson and MacKinnon (1981), is developed in the context of linear and nonlinear regression with normal errors. Each model is regarded as a special case of an artificial "supermodel" and is obtained by restricting the value of a mixing parameter gamma to 0 or 1. To enable estimation and hypothesis testing for gamma, an approximate supermodel is used in which the fitted values from the individual models appear in place of the original parametrization. In the case of nested linear models, the proposed test essentially reproduces the standard F test. The calculations required are for the most part straight-forward (basically, linear regression through the origin). The test is extended to cover situations in which serious bias in the maximum likelihood estimate of gamma occurs, simple approximate bounds for the bias being given. Two real datasets are used illustratively throughout.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Royston, S G Thompson. 1995. Comparing non-nested regression models.. https://pubmed.ncbi.nlm.nih.gov/7766768/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The influence of the spatial structure of focal hepatic lesions on volume measurements performed with two and three-dimensional sonography using the ellipsoid formula.

A total of 63 patients with localized hepatic lesions were examined using two and three-dimensional sonography. The tumor volumes were calculated by means of the ellipsoid formula, compared with an experimentally determined reference volume and subsequently differentiated into correct and erroneous measurements according to the WHO criteria for tumor volumes. In a second test series, an analysis of the tumor shapes was carried out using parallel projections. It could be seen that 65% of the erroneous measurements resulted from the use of the ellipsoid formula, a procedure which is used to determine the volume of hepatic lesions. In the third part of this study, it was found that findings which are difficult to measure are frequently not recognized as such by the investigator making use of two-dimensional sonography. As a consequence, the volume measurements of focal hepatic lesions in oncology patients being considered for particular therapies should preferably be carried out with the aid of planimetric measurements rather than with the use of the ellipsoid formula.

Biometry