Search PubMed⌕ Search

PubMed · 775974

Antacids and bleeding prophylaxis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T D McCaffrey, J Lilly. 1976. Antacids and bleeding prophylaxis.. https://doi.org/10.1007/bf01072068

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nanoparticles in wastewater from a science-based industrial park - coagulation using polyaluminum chloride.

The Hsinchu Science-based Industrial Park (HSIP) is the hi-tech manufacturing hub of Taiwan. Wastewater from the HSIP contains numerous nano-sized silicate particles whose size distributions peak at 2 and 90 nm. A 3-5 mg l(-1) as Al dose of polyaluminum chloride (PACl) was used in the field to coagulate these particles, but the removal efficiency was low. Laboratory scale tests indicated that although PACl coagulation removed 52% of the turbidity and 48% of the chemical oxygen demand (COD) from water, its effect on nano-particle removal was minimal. About 58% of the soluble COD was associated with colloidal Si particles. A light scattering test and transmission electron microscopy (TEM) demonstrated that the nano-particles agglomerated in approximately linear aggregates of sizes 100-300 nm. Prolonged contact between residual PACl and the nano-particles generated large aggregates with sizes of up to 10 microm and a fractal dimension of 2.24-2.63. The results presented herein should be of interest in the processing of "high-tech" wastewater that contains nanosized silica particles.

Aluminum Hydroxide↗

Memory effect of activated Mg-Al hydrotalcite: in situ XRD studies during decomposition and gas-phase reconstruction.

The thermal decomposition of Mg-Al hydrotalcite and the subsequent reconstruction of the decomposed products in the presence of water vapor (2 vol. % H(2)O in N(2)) have been investigated by in situ XRD. Thermographic analysis and temperature-programmed desorption MS results complemented the diffraction data. Valuable mechanistic and kinetic insights into these processes, which are of prime importance for optimal activation of this type of material for catalytic applications, were obtained. Hydrotalcite decomposition to the mixed oxide proceeds via formation at 423-473 K of an intermediate phase, consisting of a highly disordered, dehydrated, layered structure. The latter evolves by removal of interlayer water on heating, causing a shrinking of the interlayer space (it is up to 45 % smaller than in the as-synthesized hydrotalcite). Above 623 K, Mg(Al)O(x) oxide with the periclase structure is formed. Reversion of the intermediate dehydrated structure to hydrotalcite upon contact with water vapor is complete and very fast at room temperature. Recovery of hydrotalcite from the oxide calcined at 723 K is two orders of magnitude slower than rehydration of the intermediate layered structure and one order of magnitude slower than the typically practiced liquid-phase reconstruction. In contrast to the decomposition, the reconstruction mechanism does not involve an intermediate phase. The gas-phase rehydration and reconstruction was interrupted above 303 K. This is attributed to the poor wetting of the surface of the decomposed materials induced by hampered H(2)O adsorption above room temperature at the water vapor pressure applied. The Avrami-Erofe'ev model describes the reconstruction kinetics well.

Aluminum Hydroxide↗

Pretreatment of wastewater from triazine manufacturing by coagulation, electrolysis, and internal microelectrolysis.

We studied the pretreatment of concentrated wastewater from triazine manufacturing by coagulation, electrolysis, and internal microelectrolysis. Results show that coagulation by polyaluminum chloride at dosage of 0.5 g/L could remove up to 17.2% chemical oxygen demand (COD) from the wastewater. Electrolysis using iron electrode achieved 33.2% COD removal at current of 2A in 180 min, which was attributed to coagulation and oxidation of the organic contaminants in the wastewater by the radicals (OH and O) and oxidants (O2, O3, and H2O2) produced in electrochemical reactions. Internal microelectrolysis using iron chips and granular activated carbon (GAC) showed that up to 60.5% COD could be removed under the conditions of iron/GAC/wastewater volumetric ratio of 3:2:490, sparge ratio (ratio of air flow rate to volume of wastewater) of 2:490 min(-1), and reaction time of 132 h. COD reduction in internal microelectrolysis was attributed to a combination of chemical and physical processes, mainly oxidation by radicals and oxidants formed in electrochemical reactions, adsorption on, co-precipitation with, and enmeshment in ferrous and ferric hydroxides resulted from Fe2+ released during anode oxidation. The results suggest that internal microelectrolysis using iron chips and GAC is a promising, low-cost alternative for pretreating concentrated wastewater from pesticide manufacturing.

Aluminum Hydroxide↗