A computerized image analysis system for estimating Tanner-Whitehouse 2 bone age.
Abstract
A method for assigning Tanner-Whitehouse 2 skeletal maturity scores (or bone ages) to hand-wrist X-rays by an image analysis computer system is described. An operator positions the relevant area of the X-ray on a light box beneath a video camera. Correct positioning is assured by computer templates of each bone stage. Thereafter the process is automatic; the computer, not the operator, rates the bones. The system produces continuous stage scores, not discrete ones such as B, C or D. Data are given which show that the computer-assisted skeletal age score is more repeatable than the usual manual (or unassisted) rating. The absolute difference between duplicates averaged 0.25 stages; differences of as much as 1.0 stage occurred in only 3% of duplicates compared with 15% obtained in manual ratings.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J M Tanner, R D Gibbons. 1994. A computerized image analysis system for estimating Tanner-Whitehouse 2 bone age.. https://doi.org/10.1159/000184210. https://searchpubmed.org/record/pubmed%3A7698725/a-computerized-image-analysis-system-for-estimating-tanner-whitehouse-2-bone-age