Search PubMed⌕ Search

PubMed · 7670322

Electroencephalography as a localizing tool.

Abstract

1. The immature brain is not a miniature adult brain, and adult-epilepsy concepts and protocols do not necessarily apply to infant-epilepsy surgery. 2. The epileptogenic zone is conceptually, and often also topographically, distinct from both the ictal-onset zone and the irritative zone (interictal spiking). This distinction is especially important in pediatric evaluations. 3. In partial seizure disorders, the best strategy at present for demarcating the epileptogenic zone seems to be a weighted confluence of an epileptogenic lesion (if present), the ictal-onset zone, and the irritative zone. If these zones are not perfectly convergent (as is usually the case), they are given relative weights according to individual patient factors and variations in philosophy among epilepsy centers. This approach leaves much to be desired, especially in extratemporal nonlesional cases; it is hoped that future research will identify more reliable interictal markers for the epileptogenic zone. 4. Some cases of catastrophic generalized epilepsies or multifocal independent partial seizures are due to localized pathology (ZCA) and respond to resection of the offending lesion (often multilobar or hemispheric). In this context, the epileptogenic zone is coincident with the epileptogenic lesion and is best demarcated by the confluence of interictal indicators of structural pathology. The most reliable localizing aspects of the EEG are, therefore, interictal nonepileptiform abnormalities traditionally associated with structural lesions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Shewmon. 1995. Electroencephalography as a localizing tool.. https://pubmed.ncbi.nlm.nih.gov/7670322/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A Kalman filter based methodology for EEG spike enhancement.

In this work, we present a methodology for spike enhancement in electroencephalographic (EEG) recordings. Our approach takes advantage of the non-stationarity nature of the EEG signal using a time-varying autoregressive model. The time-varying coefficients of autoregressive model are estimated using the Kalman filter. The results show considerable improvement in signal-to-noise ratio and significant reduction of the number of false positives.

Electroencephalography↗

Visual evoked potential in the newborn: does it have predictive value?

We reviewed studies on the predictive value of visual evoked potentials (VEPs) in the newborn. VEPs demonstrated a good correlation with neurodevelopmental outcome in full-term infants with birth asphyxia. However, their prognostic value in preterm infants is controversial. In preterm infants, most studies showed high specificities for neurodevelopmental outcome, but some studies demonstrated lower sensitivities.

Electroencephalography↗