Search PubMed⌕ Search

PubMed · 7654973

Modeling and optimising dextrose fermentation using a fluorosensor.

Abstract

Dextrose has been fermented in a Tokyo Rikakikai Fermentor at 32 degree celsius using seven different concentrations of yeast as seeding. The progress of the reaction was followed by measuring the fluorescent signal due to NADH with a Dr. Ingold (Switzerland) fluorosensor which has an excitation wavelength of 360 nm and measurement wavelength of 450 nm. The optimum concentration for this fermentation reaction is 30 percent seeding. At this concentration the biomass growth rate and final biomass concentration are a maximum. The fluorescent voltage vs time data fitted a first order model with an error of less than one percent. Further work on optimising the temperature is in progress.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Sundaram, R Padmanabhan, S Gowrishankar, S Krithiga. 1995. Modeling and optimising dextrose fermentation using a fluorosensor.. https://searchpubmed.org/record/pubmed%3A7654973/modeling-and-optimising-dextrose-fermentation-using-a-fluorosensor

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗