Interactive intraoperative localization using an infrared-based system.

Abstract

Conventional stereotactic surgery has evolved from a ring-based system with a simple software which calculated few parameters to frameless intraoperative localization systems that provide the surgeon with real-time localization and correlation with several imaging modalities. The localization system described in this paper is an opto-electronic system that uses infrared emitters and three precalibrated CCD cameras. The system was chosen among others for the following reasons: it tracks target points defined by up to 256 miniature light emitting diodes, and its accuracy in locating the spatial position of a diode marker in the operating volume 1.0 x 1.0 m at a distance of 2.0 m is 0.1 mm with a resolution better than 0.01 mm. Systems like this one can track and define the position and orientation of any object in the field view of the camera. This is done by attaching a few small infrared emitters (light emitting diodes) to the surface of each 'rigid body' (surgical instrument) being tracked. Subsequently, through a calibration process a corresponding rigid body file is created. This rigid body file represents this particular object (i.e. surgical tool, microscope) and defines a local coordinate system that identifies each translation and orientation of that tool with respect to the camera coordinate system. This in turn is transferred into the computed tomographic/magnetic resonance imaging coordinate system by a process referred to as coordinate matching. Fiducial markers are placed on the patient's head prior to image scanning.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L J Zamorano, L Nolte, A M Kadi, Z Jiang. 1994. Interactive intraoperative localization using an infrared-based system.. https://doi.org/10.1159/000100298

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography.

The aim of this study was to evaluate gadolinium diethylenetriaminepenta-acetic acid (Gd-DTPA) as an alternative contrast agent for digital subtraction angiography (DSA) in patients with renal insufficiency or previous anaphylactic reaction to iodinated contrast agents. We performed 34 DSAs in 31 patients by use of the commercially available 0.5-M Gd-DTPA solution (Magnevist, Schering, Berlin, Germany). The contrast material was power- or hand-injected at the same rate as iodinated contrast material, without exceeding a total amount of 0.4 mmol/kg body weight. In 18 studies Gd-DTPA was the sole contrast agent. In 9 cases gadolinium injections were combined with carbon dioxide. Restricted non-ionic contrast medium injections were administered to complete the examinations in 7 cases and for comparative purposes in 1 case. Cerebral and carotid arteries, one superior limb, abdominal aorta, renal arteries, renal transplants, iliac arteries and inferior limbs were imaged, and ten endovascular interventional procedures, including three transjugular intrahepatic percutaneous stent shunts, were performed. No side effects were observed. Diagnostic angiographic images were obtained in all cases except in 5 of the 8 distal run-off studies. Gadolinium-based contrast can produce clinically useful angiograms in patients with a contra-indication to iodine who must undergo angiography.

Angiography, Digital Subtraction

[Retinal hemodynamics in patients with normal pressure glaucoma. Quantification with digital laser scanning fluorescein angiography].

UNLABELLED: Chronic ischemia of the retina and the optic nerve head seems of importance especially in patients with normal-tension glaucoma (NTG). The purpose of this study was to examine the retinal hemodynamics in patients with NTG. PATIENTS: Twenty-five patients with NTG were examined (3 weeks washout period) in this study (age 58 +/- 16 years). The arteriovenous passage (AVP) time and arterial and venous diameters from scanning laser fluorescein angiograms were evaluated by means of digital image analysis. RESULTS: The AVP time in patients with NTG (2.78 +/- 1.1 s) was significantly prolonged (P < 0.0001) compared with healthy subjects (1.58 +/- 0.4 s). No significant correlation was found between arterial and venous diameters, intraocular pressure, blood pressure or calculated perfusion pressure and retinal arteriovenous passage time. CONCLUSION: Patients with NTG showed prolonged retinal passage, which could cause chronic hypoxia. This prolongation of circulation is not correlated with any of the clinical parameters. Thus, a circulatory defect might be a primary factor in the pathogenesis of NTG.

Angiography, Digital Subtraction