Search PubMedSearch

PubMed · 7596610

Nasal implants.

Abstract

In summary, autogenous tissue remains the authors' preferred method of augmenting the nasal dorsum. Some authors have tried Supramid mesh, which tends to resorb. Mersilene seems to resist resorption and has been used with notable success. Silicone has had variable success but, because of bad publicity and the possibility of autoimmune disease, has fallen out of favor. Medpore never enjoyed widespread use over the dorsum of the nose, because of its rigidity. Gore-Tex seems to be gaining in popularity; animal studies have demonstrated its biocompatibility to be superior to that of other implants. Although the data remain preliminary at this point, they are as good as for any other implant material.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Staffel, W Shockley. 1995. Nasal implants.. https://pubmed.ncbi.nlm.nih.gov/7596610/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Metal debris from titanium spinal implants.

STUDY DESIGN: A prospective study of tissue surrounding spinal instrumentation was performed using histologic and chemical analysis. OBJECTIVES: To identify and quantify the amount of metal debris generated by titanium pedicle screw instrumentation and to evaluate the histologic response in the spinal tissues. SUMMARY OF BACKGROUND DATA: Microscopic metal particles from the soft tissue surrounding joint arthroplasties have been shown to activate a macrophage response that leads to bone resorption and increased inflammation. The use of titanium spinal implants for spine surgery projects the possibility of generating wear debris in the spine. METHODS: Nine patients with titanium instrumentation from a prior lumbar decompression and fusion procedure who were undergoing reoperation were entered into this study. Tissue samples were collected from areas near the pedicle screw-rod junction, the scar tissue overlying the dura, and the pedicle screw holes. Metal levels for titanium were determined by electrothermal atomic absorption spectroscopy, and histologic analysis was performed by light and electron microscopy. RESULTS: Tissue concentrations of titanium were highest in patients with a pseudarthrosis (30.36 micrograms/g of dry tissue). Patients with a solid fusion had low concentrations of titanium (0.586 microgram/g of dry tissue). Standard light microscopy identified metal particles in the soft tissues. Transmission electron microscopy demonstrated macrophages with numerous secondary lysosomes containing electron-dense bodies and collagenous stroma with electron-dense rod-like profiles consistent with metal debris. CONCLUSIONS: Wear debris is generated by the use of titanium spinal instrumentation in patients with a pseudarthrosis. These particles activate a macrophage cellular response in the spinal tissues similar to that seen in surrounding joint prostheses. Patients with a solid spinal fusion have negligible levels of particulate matter.

Biocompatible Materials

Conjugation of drug to poly(D,L-lactic-co-glycolic acid) for controlled release from biodegradable microspheres.

Poly(d,l-lactic-co-glycolic acid) (PLGA) was chemically conjugated to a model drug, N-(9-fluorenylmethoxycarbonyl-N-tert-butoxycarbonyl-l-tryptophan (Fmoc-Trp(Boc)) via an ester linkage. Various coupling reaction conditions were tested to optimize the conjugation process between a hydroxyl terminal group of PLGA and a carboxylic acid group of Fmoc-Trp(Boc). Two different lactic/glycolic acid compositions of PLGA (50/50 and 75/25) were used for the conjugation. The Fmoc-Trp(Boc)-PLGA conjugates were formulated into microspheres by a solvent evaporation technique for controlled release of Fmoc-Trp(Boc) over an one month period. A linear constant release of Fmoc-Trp(Boc) and its water-soluble PLGA oligomer conjugates was observed over an extended period without any initial burst effect, while unconjugated Fmoc-Trp(Boc) encapsulated within microspheres exhibited a rapid release profile. In addition, Fmoc-Trp(Boc) release rate solely depended on the PLGA composition that affected polymer degradation rate. The release rate of Fmoc-Trp(Boc) conjugated with fast degrading 50/50 PLGA was more rapid than that conjugated with relatively slow degrading 75/25 PLGA. This study demonstrates that PLGA-drug conjugation approach is a new and novel strategy to control the drug release rate from PLGA microspheres by utilizing the chemical degradation rate of PLGA backbone.

Biocompatible Materials

A controlled-release microchip.

Much previous work in methods of achieving complex drug-release patterns has focused on pulsatile release from polymeric materials in response to specific stimuli, such as electric or magnetic fields, exposure to ultrasound, light or enzymes, and changes in pH or temperature. An alternative method for achieving pulsatile release involves using microfabrication technology to develop active devices that incorporate micrometre-scale pumps, valves and flow channels to deliver liquid solutions. Here we report a solid-state silicon microchip that can provide controlled release of single or multiple chemical substances on demand. The release mechanism is based on the electrochemical dissolution of thin anode membranes covering microreservoirs filled with chemicals in solid, liquid or gel form. We have conducted proof-of-principle release studies with a prototype microchip using gold and saline solution as a model electrode material and release medium, and we have demonstrated controlled, pulsatile release of chemical substances with this device.

Biocompatible Materials