PubMed · 7576096

A patient dose verification program using diode detectors.

Abstract

In this work, we present a comprehensive patient dose verification program using a commercial dual diode detector system for external photon beam radiotherapy. To achieve acceptable accuracy, factors potentially affecting diode sensitivity need to be carefully considered in dose determination. Several authors have shown that diode sensitivity depends on temperature, saturation, linearity, radiation damage, and beam incidence angle. In addition, we found that the use of wedge filters, block trays at a close distance to the detectors, variation in radiation field size, as well as measurement SSDs may affect diode sensitivity significantly. In practice, we use a 5% dose deviation of measured dose from expected patient dose to prompt reevaluation of patient dosimetry. This yields a 90% acceptance rate in clinical patient cases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Li, L S Lamel, D Tom. 1995. A patient dose verification program using diode detectors.. https://doi.org/10.1016/0958-3947(95)00018-r

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Light-scattering submicroscopic particles as highly fluorescent analogs and their use as tracer labels in clinical and biological applications.

In a companion article we present the idea that submicroscopic light-scattering particles, such as gold and silver particles, can be used as fluorescent analog tracers in biological and clinical applications. The light-emitting power and scattered light color of the particles can be adjusted by changing particle composition or diameter. Using Rayleigh and Mie light-scattering theory, we calculated the absorbance and light-scattering properties and power of particles of different diameters and selected compositions and compared them to the properties of fluorophores. In the present article, we evaluate experimentally the optical properties of particles of selected compositions and sizes and compare the results with the theoretically calculated values. We also discuss the methods which we use to measure the light-scattering properties of particles in suspension and to view individual particles by light microscopy. We also outline examples which demonstrate the use of light-scattering particles as fluorescent analogs in biological and clinical applications.

Calibration

Quantitative analysis of modified antisense oligonucleotides in biological fluids using cationic nanoparticles for solid-phase extraction.

Based on a novel method for solid-phase extraction using cationic polystyrene nanoparticles, the suitability of the extraction procedure for quantitation of terminally and backbone-modified antisense oligonucleotides was investigated. Extractions were carried out from both human plasma and urine. Quantitative analysis of the extracted samples was performed with capillary gel electrophoresis. In accordance with previous results obtained with phosphorothioate oligonucleotides in human plasma, high linearity and accuracy of the assay was demonstrated for an oligodeoxyribonucleotide-palmityl conjugate as well as for a modified oligoribonucleotide. Optimized extraction conditions allow the isolation of oligonucleotides in high yields and purity even for concentrations in the low nanomolar range, down to 5 nM. Comparing the results obtained from human plasma and urine, no significant differences in the absolute recovery rates which reach values up to 95% were observed. However, when the loading capacity of the nanoparticles was exceeded, selective recovery was observed for the coisolation of phosphodiester and phosphorothioate oligonucleotides. This effect can be explained by differences in the attractive forces between PO- and PS-oligonucleotides and the particle surface and appears to be valuable for a modification-dependent enrichment of oligonucleotides out of complex mixtures.

Calibration

Retrospective dose reconstruction of human radiation exposure by FISH/chromosome painting.

Measurements of stable chromosomal aberrations by fluorescence in situ hybridisation (FISH)-chromosome painting has the potential to be used for dose reconstruction, years after exposure to ionising radiation. The method is, however, not yet fully standardised and validated. In particular, with respect to the limited lifespan of circulating T-lymphocytes, a level of uncertainty exists on the long-term persistence of stable aberrations. The main principles of the technique will be demonstrated. Based on results from the literature, the reliability and limitations are discussed.

Calibration