Nitric oxide administration using constant-flow ventilation.

Abstract

Nitric oxide (NO) gas is known as both a vasodilator and a toxin. It can react with oxygen to form compounds more toxic than itself, such as nitrogen dioxide (NO2). The reactions are time dependent; thus, infusing NO into breathing circuits as close to ventilated subjects as possible may help minimize toxic byproduct exposure. Unfortunately, flow rates commonly used with mechanical ventilation favor laminar gas flow (streaming) within the breathing circuits. Streaming could delay mixing of NO with other inhaled gases. This mixing delay may interfere with accurate monitoring and/or delivery of NO. We tested the hypothesis that streaming of NO infused by constant flow into the inspiratory limb of a constant-flow mechanical ventilation system can lead to NO concentration delivery estimate errors. We then compared the NO2 concentrations at the ventilator Y-piece with three different NO mixing methods: blending the gases before they reach the breathing circuit inspiratory limb, infusing NO directly into the breathing circuit inspiratory limb far enough from the Y-piece to ensure thorough mixing, and infusing NO directly into the breathing circuit inspiratory limb immediately before the gases reach an in-line mixing device placed close to the Y-piece. Our results indicate that streaming can lead to NO concentration delivery estimate errors and that these errors can be characterized by measuring NO concentration variations across the inspiratory tubing's luminal diameter. NO2 concentration measured at the ventilator Y-piece were dependent on NO concentrations (p < 0.0001), NO delivery methods (p < 0.0001), and interactions between NO concentrations and NO delivery methods (p < 0.0001). We conclude that gas streaming and toxic byproduct exposure should be considered together when choosing an NO delivery method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J W Skimming, S Cassin, P B Blanch. 1995. Nitric oxide administration using constant-flow ventilation.. https://doi.org/10.1378/chest.108.4.1065

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mechanism of melatonin-induced oscillations in the peroxidase-oxidase reaction.

Melatonin induces oscillations in the peroxidase-oxidase (PO) reaction catalyzed by horseradish peroxidase. We present here studies of the effect of pH, enzyme concentration, and concentration of melatonin on the oscillation frequency. We also present a mechanistic model to explain the experimentally observed changes in oscillation frequency. Using the data obtained here we are able to predict that oscillations will also occur in the PO reaction catalyzed by myeloperoxidase. Myeloperoxidase is an important protein in activated neutrophils and we provide evidence that the oscillations of NAD(P)H, superoxide and hydrogen peroxide in these cells may involve this enzyme. Thus, our experimental system can be considered a model system for the nonrespiratory oxygen metabolism in activated neutrophils and other similar cells participating in the defence against invading pathogens.

Dose-Response Relationship, Drug↗

Mg2+ ion effect on conformational equilibrium of poly A . 2 poly U and poly A poly U in aqueous solutions.

Differential UV spectroscopy and thermal denaturation were used to study the Mg(2+) ion effect on the conformational equilibrium in poly A.2 poly U (A2U) and poly A . poly U (AU) solutions at low (0.01 M Na(+)) and high (0.1 M Na(+)) ionic strengths. Four complete phase diagrams were obtained for Mg(2+)-polynucleotide complexes in ranges of temperatures 20-96 degrees C and concentrations (10(-5)-10(-2)) M Mg(2+). Three of them have a 'critical' point at which the type of the conformational transition changes. The value of the 'critical' concentration ([Mg(t)(2+)](cr)=(4.5+/-1.0) x 10(-5) M) is nearly independent of the initial conformation of polynucleotides (AU, A2U) and of Na(+) contents in the solution. Such a value is observed for Ni(2+) ions too. The phase diagram of the (A2U+Mg(2+)) complex with 0.01 M Na(+) has no 'critical' point: temperatures of (3-->2) and (2-->1) transitions increase in the whole Mg(2+) range. In (AU+Mg(2+)) phase diagram at 0.01 M Na(+) the temperature interval in which triple helices are formed and destroyed is several times larger than at 0.1 M Na(+). Using the ligand theory, a qualitative thermodynamic analysis of the phase diagrams was performed.

Dose-Response Relationship, Drug↗