Search PubMed⌕ Search

PubMed · 7552694

Multiple peptide synthesis.

Abstract

The synthesis of large numbers of peptides can be very labor intensive and, if a conventional peptide synthesizer is used, only small numbers of peptides can be produced within a reasonable time. The techniques described below can make large numbers of different peptides simultaneously with varying degrees of mechanization, ranging from the wholly manual methods, to those involving complete mechanization of the whole synthesis process. Most of the multiple synthesis methods are primarily intended for small scale production ranging from microgram amounts up to a few tens of milligrams. All of the systems are economical in use of solvents and reagents, enabling cost-effective synthesis. The techniques described can also be used to prepare peptide libraries, containing several millions of peptide sequences, to enable the rapid screening of all possible permutations of amino acids within short peptides. However, it is considered that multiple synthesis methods are not particularly suited where extreme high purity or very long peptides are required.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J E Fox. 1995. Multiple peptide synthesis.. https://doi.org/10.1007/bf02789335

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of valdecoxib and its metabolites in human urine by automated solid-phase extraction-liquid chromatography-tandem mass spectrometry.

A simple, sensitive and specific automated SPE-LC-MS-MS assay was developed and validated for determination of valdecoxib (I), its hydroxylated metabolite (II) and carboxylic acid metabolite (III) in human urine. The analytes (I, II and III) and a structural analogue internal standard (I.S.) were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was performed on a narrow-bore reverse phase HPLC column with a mobile phase of acetonitrile-water (50:50, v/v) containing 10 mM 4-methylmorpholine (pH 6.0). The analytes were ionized using negative electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 313-->118, m/z 329-->196 and m/z 343-->196 were used to measure I, II and III, respectively. The assay exhibited a linear dynamic range of 1-200 ng/ml for I and II and 2-200 ng/ml for III in human urine. The lower limit of quantitation was 1 ng/ml for I and II and 2 ng/ml for III. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 5.5 min for each sample made it possible to analyze a throughput of 70 human urine samples per run. The assay has been successfully used to analyze human urine samples to support clinical phase I and II studies.

Automation↗

Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification.

A continuous segmented-flow method for sequential DNA amplification is described in order to provide a basis for high-throughput genetic analysis. The approach allows an immediate distinction between amplified and nonamplified products. A mixture of sample and reagents are loaded in the form of small segments one after another in a 15-m-long narrow-bore Teflon tube, coiled such as to be repeatedly exposed to three different temperature zones. After having passed the heated zones, the samples are mixed with an intercalating dye by flow injection and sequentially detected on-line by laser-induced fluorescence. The aqueous samples travel as separate segments in a continuous flow of an immiscible, organic liquid. Perfluorodecalin was shown to be particularly suitable due to its hydrophobicity and inert properties. To reduce carryover between samples, an intermediate water plug between two consecutive samples was required. Selected regions from human genomic DNA were successfully amplified in 300-nL volumes after 30 passes through the heated zones. The total reaction time was approximately 45 min, and the detection interval between individual samples was 1 min. Automation and the possibility to further reduce sample volumes, as well as to employ many reaction columns simultaneously, should provide a platform for an extremely high throughput.

Automation↗