Search PubMedSearch

PubMed · 7508616

Permanent pacemaker lead extraction.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Sloman, N Strathmore. 1993. Permanent pacemaker lead extraction.. https://doi.org/10.1111/j.1540-8159.1993.tb02345.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Initial experience with a high-impedance tined endocardial pacemaker lead: evidence for increased lead failure.

We report our initial clinical experience with a new tined ventricular endocardial pacemaker lead, the Medtronic model 5034. This lead has a reduced electrode tip size, which provides a higher impedance. Based on early evidence of elevation of pacing lead threshold, we compared our clinical experience with the performance of this lead with that of other similar models with larger surface area (Medtronic models 4024 and 5024). Of 17 implant procedures performed at our institution with the model 5034 lead, two (11.2%) developed high thresholds, versus 0% in 121 implant procedures with models 4024 or 5024 leads (p = 0.014). We conclude that there is evidence of increased failure caused by elevation of pacing threshold in this lead. This increased failure rate needs to be confirmed in a multicenter observational study or randomized trial.

Electrodes, Implanted

Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique.

BACKGROUND: In spite of advances in noninvasive localization of seizure foci, some cases of intractable limbic epilepsy still require invasive recordings in order to identify the site of seizure onset. This necessitates a safe and reliable method for placing depth and subdural electrodes in the mesial temporal and orbitofrontal regions. The University of Florida has devised a system that utilizes CRW-based stereotactic placement of bitemporal depth electrodes in conjunction with placement of subdural strips over the inferolateral temporal lobe and orbitofrontal cortex. This report describes the surgical technique and initial clinical experience using this method. METHODS: Depth electrodes are placed along the long axis of the hippocampi via an occipital approach. A CRW-based stereotactic system was developed that incorporates both computed tomography (CT) and magnetic resonance imaging (MRI) for selection of target and entry sites and displaying the electrode trajectory. Subdural strip electrodes are placed over the inferolateral temporal and orbitofrontal regions through burr holes. RESULTS: This method has been used in 18 patients (depth electrodes only in three patients and depth electrodes with subdural strips in 15 patients). This information lead to surgical resections in 15 patients. No resection was recommended in three patients (two with bitemporal onset and one with no seizures after 6 weeks). Complications were limited to an unplanned removal of one electrode and an asymptomatic lateral temporal lobe contusion in one patient. CONCLUSIONS: This method provides a safe and effective way to sample bilateral mesial temporal and orbitofrontal regions in cases of intractable limbic epilepsy.

Electrodes, Implanted