Search PubMedSearch

PubMed · 7497756

Abnormal ventricular long-axis function in systemic sclerosis.

Abstract

STUDY OBJECTIVE: To assess possible effects of systemic sclerosis on ventricular function. DESIGN: Retrospective analysis of patients referred for echocardiographic examination to assess ventricular function. SETTING: Tertiary referral center for cardiac and chest diseases equipped with invasive and noninvasive facilities. PATIENTS: Thirty-four patients with clinical diagnosis of systemic sclerosis, aged 49 +/- 12 years; 24 had pulmonary fibrosis and 10 did not. There were 21 normal controls of similar age. MEASUREMENTS: Two-dimensional guided M-mode echocardiographic recordings of the left ventricular minor and long axis at the left and septal sites and right ventricle were obtained. Transmitral and transtricuspid Doppler flow velocities were also obtained with ECG and phonocardiogram. RESULTS: In 24 patients with pulmonary fibrosis, long-axis excursion was reduced 2.1 +/- 0.5 vs 2.7 +/- 0.4 cm/s as was peak rate of shortening and lengthening, 8.5 +/- 3.3 vs 10.8 +/- 2.4 cm/s and 7.5 +/- 2.5 vs 12 +/- 3.6 cm/s, respectively (p < 0.001), at the right side compared with 10 patients without. The onset of right long-axis shortening and lengthening was delayed with respect to the Q wave of the ECG and P2 of the phonocardiogram (p < 0.001 in both vs controls). The onset of tricuspid forward flow from the second heart sound was also delayed in the two groups, 110 +/- 15 ms and 100 +/- 20 ms vs 80 +/- 15 ms, respectively (p < 0.001). Right ventricular late diastolic filling velocities were increased 35 +/- 15 and 35 +/- 12 cm/s vs 20 +/- 10 cm/s in both groups (p < 0.01), and hence E:A ratio reduced 1.25 +/- 0.5 and 1.4 +/- 0.3 vs 1.9 +/- 0.4, respectively (p < 0.001). Pulmonary flow acceleration time was reduced only in patients with pulmonary fibrosis, 105 +/- 30 ms vs 125 +/- 30 ms (p < 0.001). At the left side, total long-axis excursion was reduced only in patients with pulmonary fibrosis (p < 0.01), while peak shortening and lengthening rates were reduced in both groups (p < 0.05). The onset of shortening from the Q wave and lengthening from the second heart sound were both delayed in the two groups with the latter greatly delayed in patients with pulmonary fibrosis (p < 0.05). CONCLUSIONS: Right and left ventricular long-axis function is frequently abnormal in patients with systemic sclerosis. Abnormalities are more profound in patients with CT evidence of pulmonary fibrosis than in those without. We suggest that these disturbances are due to myocardial fibrosis which, from the anatomic distribution of longitudinally directed fibers, is likely to have been subendocardial.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Y Henein, J Cailes, C O'Sullivan, R M du Bois, D G Gibson. 1995. Abnormal ventricular long-axis function in systemic sclerosis.. https://doi.org/10.1378/chest.108.6.1533

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

TIMI frame count: a quantitative method of assessing coronary artery flow.

BACKGROUND: Although the Thrombolysis in Myocardial Infarction (TIMI) flow grade is valuable and widely used qualitative measure in angiographic trials, it is limited by its subjective and categorical nature. METHODS AND RESULTS: In normal patients and patients with acute myocardial infarction (MI) (TIMI 4), the number of cineframes needed for dye to reach standardized distal landmarks was counted to objectively assess an index of coronary blood flow as a continuous variable. The TIMI frame-counting method was reproducible (mean absolute difference between two injections, 4.7 +/- 3.9 frames, n=85). In 78 consecutive normal arteries, the left anterior descending coronary artery (LAD) TIMI frame count (36.2 +/- 2.6 frames) was 1.7 times longer than the mean of the right coronary artery (20.4 +/- 3.0) and circumflex counts (22.2 +/- 4.1, P < .001 for either versus LAD). Therefore, the longer LAD frame counts were corrected by dividing by 1.7 to derive the corrected TIMI frame count (CTFC). The mean CTFC in culprit arteries 90 minutes after thrombolytic administration followed a continuous unimodal distribution (there were not subpopulations of slow and fast flow) with a mean value of 39.2 +/- 20.0 frames, which improved to 31.7 +/- 12.9 frames by 18 to 36 hours (P < .001). No correlation existed between improvements in CTFCs and changes in minimum lumen diameter (r=-.05, P=.59). The mean 90-minute CTFC among nonculprit arteries (25.5 +/- 9.8) was significantly higher (flow was slower) compared with arteries with normal flow in the absence of acute MI (21.0 +/- 3.1, P < .001) but improved to that of normal arteries by 1 day after thrombolysis (21.7 +/- 7.1, P=NS). CONCLUSIONS: The CTFC is a simple, reproducible, objective and quantitative index of coronary flow that allows standardization of TIMI flow grades and facilitates comparisons of angiographic end points between trials. Disordered resistance vessel function may account in part for reductions in flow in the early hours after thrombolysis.

Blood Flow Velocity