Analysis of errors in parameter estimation with application to physiological systems.

Abstract

The accuracy of parameter estimation applied to physiological systems is analyzed. The method of analysis is applicable to procedures utilizing minimization of squared output error and a nonlinear dynamic system model. Three major sources of estimation error are described: 1) measurement error, 2) modeling error, and 3) optimization error. Measurement errors affect values used for the system output, the model input, and nonestimated parameters of the model. Modeling errors are due to failure to adequately describe the structure of the system and to numerical errors that occur in the digital computer solution of the model equations. Linearization by use of Taylor series expansions in the region of the nominal solution is used to obtain an expression for the covariance matrix of the parameter estimates in terms of the covariance matrix of each error source. The analysis is applied to the example of cardiac output estimation from respiratory measurements. The results demonstrate that an analysis of system identifiability is not sufficient to ensure usable estimates and that systematic error analysis is essential for assessing the usefulness of parameter estimation techniques.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T M Grove, G A Bekey, L J Haywood. 1980. Analysis of errors in parameter estimation with application to physiological systems.. https://doi.org/10.1152/ajpregu.1980.239.5.r390

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children.

The purpose of this study was to evaluate the reliability of a thoracic electrical bioimpedance based device (PhysioFlow) for the determination of cardiac output and stroke volume during exercise at peak oxygen uptake (peak VO(2) in children. The reliability of peak VO(2) is also reported. Eleven boys and nine girls aged 10-11 years completed a cycle ergometer test to voluntary exhaustion on three occasions each 1 week apart. Peak VO(2) was determined and cardiac output and stroke volume at peak VO(2) were measured using a thoracic bioelectrical impedance device (PhysioFlow). The reliability of peak VO(2) cardiac output and stroke volume were determined initially from pairwise comparisons and subsequently across all three trials analysed together through calculation of typical error and intraclass correlation. The pairwise comparisons revealed no consistent bias across tests for all three measures and there was no evidence of non-uniform errors (heteroscedasticity). When three trials were analysed together typical error expressed as a coefficient of variation was 4.1% for peak VO(2) 9.3% for cardiac output and 9.3% for stroke volume. Results analysed by sex revealed no consistent differences. The PhysioFlow method allows non-invasive, beat-to-beat determination of cardiac output and stroke volume which is feasible for measurements during maximal exercise in children. The reliability of the PhysioFlow falls between that demonstrated for Doppler echocardiography (5%) and CO(2) rebreathing (12%) at maximal exercise but combines the significant advantages of portability, lower expense and requires less technical expertise to obtain reliable results.

Cardiac Output↗

Clinical assessment of cardiac performance in infants and children following cardiac surgery.

OBJECTIVE: To compare clinical assessment of cardiac performance with an invasive method of haemodynamic monitoring. DESIGN AND SETTING: Prospective observational study in a 16-bed tertiary paediatric intensive care unit. PATIENTS AND PARTICIPANTS: Infants and children undergoing cardiopulmonary bypass and surgical repair of congenital heart lesions. INTERVENTIONS: Based on physical examination and routinely available haemodynamic monitoring in the paediatric intensive care unit, medical and nursing staff assessed cardiac index, systemic vascular resistance index and volume status. Clinical assessment was compared with cardiac index, systemic vascular resistance index and global end diastolic volume index, obtained by femoral artery thermodilution. MEASUREMENTS AND RESULTS: A total of 76 clinical estimations of the three parameters were made in 16 infants and children undergoing biventricular repair of congenital heart lesions. Agreement was poor between clinical and invasive methods of determining all three studied parameters of cardiac performance. Cardiac index was significantly underestimated clinically; mean difference was 0.71 l min(-1) m(-2) (95% range of agreement +/-2.7). Clinical estimates of systemic vascular resistance (weighted kappa=0.15) and volume status (weighted kappa=0.04) showed poor levels of agreement with measured values and were overestimated clinically. There was one complication related to a femoral arterial catheter and one device failure. CONCLUSIONS: Routine clinical assessment of parameters of cardiac performance agreed poorly with invasive determinations of these indices. Management decisions based on inaccurate clinical assessments may be detrimental to patients. Invasive haemodynamic monitoring using femoral artery thermodilution warrants cautious further evaluation as there is little agreement with clinical assessment which is presently standard accepted care in this patient population.

Cardiac Output↗