Search PubMedSearch

PubMed · 7316392

Comparative study using computed tomographic thin-section zoom reconstructions and anatomic macrosections of the temporal lobe.

Abstract

Thin-section (1.5 mm) high-spatial-resolution computed tomography (CT) in combination with computerized high-resolution image reconstruction is an effective, noninvasive means of studying patients with a variety of temporal bone abnormalities. To determine what degree of definition and anatomic accuracy could currently be obtained by using these techniques, we performed thin-section CT and high-resolution image reconstruction with use of two fresh-frozen cadaver head specimens. We then compared these images with the actual anatomic macrosections subsequently obtained from the specimens. We concluded that high-resolution CT scans of temporal bone can produce accurate, highly detailed, diagnostic images of the internal auditory canal, vestibule, cochlea, vestibular aqueduct, semicircular canals, and middle ear space.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C W Beatty, K W Suh, L D Harris, D F Reese. Comparative study using computed tomographic thin-section zoom reconstructions and anatomic macrosections of the temporal lobe.. https://doi.org/10.1177/000348948109000629

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Efficacy and kinetics of glycerol inactivation of HIV-1 in split skin grafts.

Allogeneic split skin grafts are used widely in the treatment of burns. The relative simplicity of glycerol preservation of skin suggests it will be used increasingly in areas of high HIV-1 seroprevalence. The ability of glycerol preservation to inactivate HIV-1 present in skin graft infected in vitro was determined using a macrophage tropic strain HIV-1 as a cell-free virus suspension, within infected PBMCs, or within in vitro HIV-1 infected fresh cadaveric split skin. Different temperatures and concentrations of glycerol were used and infectivity determined by coculture with mitogen activated peripheral blood mononuclear cells (PBMCs) and measurement of reverse transcriptase activity after 7-10 days. Cell-free HIV-1 was inactivated within 30 min at 4 degrees C in glycerol concentrations of 70% or higher. During similar exposure cell- or skin-associated HIV-1 titer was reduced but not eliminated with 70% and 85% glycerol at 4 degrees C. HIV-1 was recovered consistently from skin stored in 85% glycerol at 4 degrees C for up to 72 hr but virus isolation was infrequent after storage for more than 5 days. At 20 degrees C or 37 degrees C, 70% or 85% glycerol could inactivate cell- or skin-associated HIV-1 within 8 hr. The initial glycerolization procedures and the storage at 4 degrees C eliminated effectively HIV-1 from skin.

Cadaver

Hinged external fixation of the elbow: optimal axis alignment to minimize motion resistance.

OBJECTIVE: To establish an optimal single hinge axis position for application of hinged external fixation to the elbow joint. DESIGN: Cadaveric biomechanical investigation. SETTING: A customized motion transducer applied passive elbow motion to six cadaveric upper extremities. The instant rotation axis of the humero-ulnar articulation was determined from three-dimensional kinematic data acquired by an electromagnetic motion tracking system. For each specimen, an optimal fixator hinge position was calculated from these motion data. INTERVENTION: A prototype articulated external fixator was applied to the elbow, first with its hinge aligned along the computed optimal position. Then the fixator was mounted in sixteen distinct off-axis positions. MAIN OUTCOME MEASURE: Additional resistance to joint motion (in terms of energy) corresponding to deliberately introduced amounts of relative malalignment between the optimal elbow axis and the actual fixator hinge axis. RESULTS: Aligning the fixator hinge along the optimized axis position resulted in a minimal amount of energy (0.15 joules) needed to rotate the elbow through a prescribed range of motion. Malpositioning the hinge by ten millimeters caused up to ten times that amount of motion resistance. CONCLUSIONS: An optimal fixator hinge position can be determined to minimize the increase in motion resistance due to fixator application. The severely increased motion resistance associated with small amounts of malalignment between the fixator hinge and the anatomic elbow axis suggests the need for highly accurate fixator hinge application.

Cadaver

The economic implications of HLA matching in cadaveric renal transplantation.

BACKGROUND: The potential economic effects of the allocation of cadaveric kidneys on the basis of tissue-matching criteria is controversial. We analyzed the economic costs associated with the transplantation of cadaveric kidneys with various numbers of HLA mismatches and examined the potential economic benefits of a local, as compared with a national, system designed to minimize HLA mismatches between donor and recipient in first cadaveric renal transplantations. METHODS: All data were supplied by the U.S. Renal Data System. Data on all payments made by Medicare from 1991 through 1997 for the care of recipients of a first cadaveric renal transplant were analyzed according to the number of HLA-A, B, and DR mismatches between donor and recipient and the duration of cold ischemia before transplantation. RESULTS: Average Medicare payments for renal transplant recipients in the three years after transplantation increased from 60,436 dollars per patient for fully HLA-matched kidneys (those with no HLA-A, B, or DR mismatches) to 80,807 dollars for kidneys with six HLA mismatches between donor and recipient, a difference of 34 percent (P<0.001). By three years after transplantation, the average Medicare payments were 64,119 dollars for transplantations of kidneys with less than 12 hours of cold ischemia time and 74,997 dollars for those with more than 36 hours (P<0.001). In simulations, the assignment of cadaveric kidneys to recipients by a method that minimized HLA mismatching within a local geographic area (i.e., within one of the approximately 50 organ-procurement organizations, which cover widely varying geographic areas) produced the largest cost savings (4,290 dollars per patient over a period of three years) and the largest improvements in the graft-survival rate (2.3 percent) when the potential costs of longer cold ischemia time were considered. CONCLUSIONS: Transplantation of better-matched cadaveric kidneys could have substantial economic advantages. In our simulations, HLA-based allocation of kidneys at the local level produced the largest estimated cost savings, when the duration of cold ischemia was taken into account. No additional savings were estimated to result from a national allocation program, because the additional costs of longer cold ischemia time were greater than the advantages of optimizing HLA matching.

Cadaver