Search PubMed⌕ Search

PubMed · 7260019

Quantitative trabeculectomy.

Abstract

The technique and results of a trabeculectomy are presented where the desired final intraocular pressure (IOP) is obtained by means of adjusting the thickness of sclerocorneal tissue removed to the initial pressure. The procedure was used in 35 eyes with all types of glaucoma and pre-operative pressures of up to 50 mmHg. In 78.3% of cases one operation was sufficient to control the IOP without additional medication. Two eyes had to be reoperated on, and 7 more needed additional pressure-lowering medication. The overall success rate, therefore, rose to 97.3%. The only failure occurred in an eye with irreducible acute angle-closure glaucoma where malignant glaucoma complicated the trabeculectomy. Complications included hyphaema (3), shallow anterior chamber (7)--with or without choroidal detachment--and transient rise in the IOP. All complications subsided with conservative therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R David, U Sachs. 1981. Quantitative trabeculectomy.. https://doi.org/10.1136/bjo.65.7.457. https://searchpubmed.org/record/pubmed%3A7260019/quantitative-trabeculectomy

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗