Search PubMedSearch

PubMed · 7173539

[Sinus node electrogram in the evaluation of sinus node function].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Padeletti, A Michelucci, G A Fradella, D Monizzi, R Molino Lova, F Fantini. 1982. [Sinus node electrogram in the evaluation of sinus node function].. https://pubmed.ncbi.nlm.nih.gov/7173539/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of late postoperative atrial septal defect closure on hemodynamic function in patients with a Lateral tunnel Fontan procedure.

OBJECTIVES: The aim of this study was to evaluate prospectively the effect of late atrial septal defect closure on cardiac output and oxygen delivery in patients who have undergone the Fontan procedure. BACKGROUND: An adjustable atrial septal defect is incorporated in patients undergoing the Fontan procedure who have increased pulmonary vascular resistance or poor ventricular function, or both. After the Fontan procedure, the atrial septal defect is test occluded. Patients with mean right atrial and pulmonary artery pressures > 15 mm Hg are discharged with the atrial septal defect open. METHODS: Twelve patients (20 months to 12 years old) underwent evaluation and closure of the atrial septal defect at a mean interval of 3.8 months (range 1 to 18) after the Fontan procedure. Each patient underwent full right and left heart catheterization. Cardiac output was obtained using the cine-volume method. The study included six patients with a high transpulmonary gradient or poor ventricular function preoperatively, or both (high risk group) and six who had only borderline increased pulmonary vascular resistance (low risk group). Patients in both groups had a mean right atrial pressure > 15 mm Hg when the atrial defect was test occluded in the first week after the Fontan procedure. RESULTS: All results are given as mean value +/- SD. Ventricular end-diastolic pressure was significantly lower (p = 0.03) with the atrial septal defect open in low risk patients (6 +/- 3 mm Hg) than in high risk patients (10 +/- 3 mm Hg). With the atrial septal defect open, low risk patients had a significantly higher (p = 0.04) cardiac index (4.87 +/- 0.81 liters/min per m2) than the high risk patients (3.96 +/- 0.47 liters/min per m2). There was no significant difference (p = 0.14) in cardiac index between the two groups with occlusion of the atrial septal defect. Oxygen delivery was also significantly higher (p < 0.05) with the atrial septal defect open in low risk patients (836 +/- 99 ml/min per m2) than in high risk patients (704 +/- 106 ml/min per m2). There was no significant difference (p = 0.89) in oxygen delivery between the two groups with occlusion of the atrial septal defect. With the atrial septal defect open, the interatrial gradient was not significantly different in low risk patients (4 +/- 1 mm Hg) from that in high risk patients (4 +/- 1 mm Hg). CONCLUSIONS: These data show that an interatrial communication results in increased postoperative systemic perfusion and oxygen delivery in patients with good diastolic ventricular function after the Fontan procedure.

Atrial Function

An in vitro evaluation of venous cannula in a simulated partial (femoro-femoral) cardiopulmonary bypass circuit.

We designed a study to evaluate three factors (siphon gradient [PH], the right atrial pressure [RAP], and the inferior vena caval flow [IVCF]) to be optimized to maximize the venous drainage flow (DF) during partial cardiopulmonary bypass using eight venous cannulas of three different types and an original model circuit. The relationship between venous DF and the three factors is indicated by the multiple regression equation DF2 = alpha PH + beta RAP + gamma IVCF2 + C, where alpha, beta, and gamma are regression estimates and C is a constant. Multiple regression analysis results showed that DF was positively correlated with PH and RAP and negatively correlated with IVCF. A long cannula with 12 side holes and 60 cm long was considered to be useful to yield the optimal venous drainage flow under the condition of maintenance of the flow balance (DF and ICVF) and the pressure balance (RAP and IVCP) at the zero point. Moreover, this model may allow extensive research in flow dynamics of venous cannula without involving human subjects.

Atrial Function

Pure atrial-based lower rate timing of dual chamber pacemakers: implications for upper rate limitation.

The release of dual chamber pulse generators with atrial-based lower rate timing has added a new dimension to the complexity of pacemaker function and electrocardiography. This discussion focuses on the concept that in pulse generators with pure atrial-based lower rate timing, preservation of the atrial lower rate interval takes hierarchical precedence over all other timing intervals including the ventricular-based upper rate interval. Under certain circumstances whenever upper rate limitation requires extension of the programmed AV interval, a DDD pulse generator with pure atrial-based lower rate timing can violate its atrial-driven upper rate interval to provide constancy of the lower rate interval. Such behavior also has important implications for upper rate control in devices that function in the DDI (DDIR) or DDDR mode with pure atrial-based lower rate timing.

Atrial Function