Search PubMedSearch

PubMed · 7093086

Computerised cardiological case notes.

Abstract

Optical Mark Reader forms have been used by the Cardiac Department at St Thomas's Hospital for six years to store clinical and haemodynamic data by computer. Forms are completed by clinical staff in outpatients and also for those patients undergoing cardiac catheterisation. Three documents are used to record the symptoms and signs at the clinical consultation, the results of relevant investigations, and the important findings at cardiac catheterisation. These documents are fed into a computer and data from them, together with a limited quantity of types information, are used to produce full clinical reports for our colleagues and the case notes. There reports have saved much secretarial and medical time. A variety of analyses is available for research and management purposes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K N Williams, I A Brooksby, J Morrice, S Houseago, M M Webb-Peploe. 1982. Computerised cardiological case notes.. https://doi.org/10.1136/hrt.48.2.169

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of the Terumo SP catheter system for crossing the pulmonary valve in infants with critical pulmonary valve stenosis.

In short, this method (the Terumo SP hydrophilic-polymer coated microcatheter system) has proved to be safe, effective, and flexible; it has allowed us to cross critically stenotic valves when standard methods have failed, enabling us to accomplish balloon valvuloplasty with good results in patients who might have otherwise required surgical intervention because of inability to cross the pulmonary valve.

Cardiac Catheterization

Paracrine coronary endothelial control of left ventricular function in humans.

BACKGROUND: Similar to endothelial modulation of vascular tone, myocardial contraction may be modulated by cardioactive agents released from the coronary endothelium. To investigate such modulation in humans, we performed invasive assessment of left ventricular (LV) function before, during, and after bicoronary infusion of substance P, which releases nitric oxide from the endothelium. METHODS AND RESULTS: Eight healthy subjects were investigated during diagnostic coronary angiography and eight transplant recipients during annual catheterization. Tip-micromanometer LV pressure was recorded before, during, and after bicoronary (n = 16) and right atrial (n = 14) infusion of substance P (20 pmol/min). LV angiograms (n = 11) were obtained before and at the end of the substance P infusion. At the end of the intracoronary substance P infusion, we observed (1) a fall in LV peak systolic pressure from 147 +/- 16 to 139 +/- 15 mm Hg (P < .01) in healthy subjects and from 147 +/- 25 to 141 +/- 22 mmHg (P < .05) in transplant recipients; (2) a downward and rightward shift of the average LV end-systolic pressure-volume point consistent with depressed systolic performance; and (3) a rise in LV end-diastolic volume at comparable end-diastolic pressure, consistent with increased end-diastolic distensibility. Five minutes after the substance P infusion, LV peak systolic pressure was higher than at baseline in healthy subjects (154 +/- 18 mm Hg; P < .05). Right atrial infusion of substance P did not reproduce these changes. CONCLUSIONS: Bicoronary infusion of substance P modulates LV function in humans, probably through paracrine myocardial action of cardioactive agents released from the coronary endothelium.

Cardiac Catheterization